Operating Instructions
Clean electrodes
!
Unlock and remove the suction
head
!
Clean electrodes
!
Replace the suction head and
lock it in place
NT 361 Eco / NT 361 Eco TE
Fault instructions
The suction turbine does not
run
!
Check the cable, plug, fuse and
socket.
!
Switch on the machine.
The suction turbine switches off
!
Empty the container.
The suction turbine does not
restart following emptying of
the container
!
Switch the appliance off and
wait for 5 s, switch it on again
after 5 s.
!
Clean the electrodes as well as
the space between them.
The suction power decreases
!
Remove the parts clogging up
the suction nozzle, the suction
tube, the Power Filter Clean
handle, the suction hose or the
flat pleat filter.
!
Change the paper filter bag.
!
Actuate the filter
cleaner: Power Filter Clean
several times at the handle.
!
Engage the filter cover
properly.
!
Replace the flat pleat filter.
Dust ejects when sucking
!
Check the proper mounting
position of the flat pleat filter.
!
Replace the flat pleat filter.
The (wet-vacuuming) automatic
switch-off does not respond
!
Clean the electrodes as well as
the space between them.
!
Constantly check fill level when
vacuuming electrically non-
conductive liquids.
English
Power Filter Clean switches
regularly
!
Detach blocked suction nozzle
or end of hose.
!
Stop continuous vacuuming
from liquid tank or deactivate
the Power Filter Clean function
(see chapter on wet-
vacuuming).
!
Remove the parts clogging up
the suction nozzle, the suction
tube, the Power Filter Clean
handle, the suction hose or the
flat pleat filter.
!
Replace the flat pleat filter.