Gas type conversion

Converting from LPG to natural gas

Removing the gas restrictor
B
F
A
C
E D
1. Pull cable from gas train A.
2. Undo union nut B.
3. Undo 2 screws C and remove gas
train A.
4. Remove gas restrictor D from gas
train A.
5. Mount gas train A with new gaskets
E and F.
!
Please note
Tighten screws just enough
to ensure the components do
not suffer damage and will
function correctly.
76
6. Remove or void gas type sticker on
the top of the boiler (next to the type
plate).
7. Start the boiler and check for leaks.
Danger
Escaping gas leads to a risk of
explosion.
Check all gas equipment for
tightness.