How To Operate The Machine - Air Burners T-300 Operating Manual

Air curtain burner
Table of Contents

Advertisement

T-300
Air Curtain Trench Burner with Perkins 404D.22T or Kubota V2403-TE Engine
DANGER:
THE MACHINE MUST
ONLY BE OPERATED WITH THE TOP
COWLING CLOSED AND SECURED.
PRE-CHECKS
Check all belts and fluids.
Make sure the top cowling is down and locked and
secured.
Make sure the clutch (PTO) is disengaged (the
lever in the down position).
Make sure the engine speed control is at minimum
by turning the black speed knob clockwise.
STARTING
If preheat is needed, press the PREHEAT switch
for maximum six seconds.
To START
(a) the Perkins engine, push the start button and
hold down the oil pressure override button.
(b) the Kubota engine, turn key clockwise and hold
for three seconds after engine starts (this will
override the oil pressure cut-off sensor, until oil
pressure builds up).
WARM-UP the engine at Idle speed of 1,000 RPM for 5
to 10 minutes before engaging the fan at 1,400 RPM +/-
200 RPM.
Engage the AIR FAN by slowly engaging the
clutch lever to the "up" position until it locks
into place. Engaging the clutch too fast or at
higher RPM may cause the air fan drive belts to
jump the drive pulleys.

HOW TO OPERATE THE MACHINE

Page 14 of 34
Air Burners, Inc.
OPERATING MANUAL
Clutch (PTO) Lever, Fuel Filler
Perkins 404D Control
Panel Housing
Perkins 404D Start/Stop
"Murphy" Switch
(Vers. 08.16)