DANGER:
THE MACHINE MUST
ONLY BE OPERATED WITH THE TOP
COWLING CLOSED AND SECURED.
PRE-CHECKS
Check all belts and fluids.
Make sure the optional battery disconnect is
engaged.
Make sure the top cowling is down and
locked and secured.
Make sure the clutch (PTO) is disengaged
(the lever in the down position).
Make sure the engine speed control is at
minimum by turning the black speed knob
clockwise.
STARTING
If preheat is needed, press the PREHEAT
switch for maximum six seconds.
To START the engine, turn key clockwise
and hold for three seconds after engine starts
(this will override the oil pressure cut-off sen-
sor, until oil pressure builds up).
WARM-UP the engine at Idle speed of 1,000
RPM for 5 to 10 minutes before engaging the fan
at 1,400 RPM +/- 200 RPM.
Engage the FAN by slowly engaging the
clutch lever to the "up" position until it
locks into place. Engaging the clutch too
fast or at higher RPM may cause the air
fan drive belts to jump the drive pulleys.