Parameters Setting - Baxi Luna 3+ Operating And Installation Instructions

Table of Contents

Advertisement

Available languages

Available languages

To set the boiler parameters press the R and
the display shows "F01" alternated with the value of the parameter.

Parameters setting

Press +/-
buttons for scrolling parameters;
Press +/-
buttons to change the single parameter
value;
Press the P button to save changes, the display
shows "MEM";
Press the
button to leave the function without
saving, the display shows "ESC";
Description of parameter
Type of gas boiler
F01
10 = sealed chamber
20 = atmospheric chamber
Type of gas
F02
00 = natural (metane) - 01 = LPG
Hydraulic system
00 = instantaneous appliance
F03
05 = appliance with external storage boiler
08 = appliance for heating only
Programmable relay 1 setting
F04
2 = zone system (See SERVICE Instructions)
Programmable relay 2 setting
F05
13 = "cool" function for external air-conditioning
system (See SERVICE Instructions)
External sensor programmable input setting
F06
(See SERVICE Instructions)
F07...F12
Manufacturer information
F13
CH max. heating output (0-100%)
F14
D.H.W. max. heating output (0-100%)
F15
CH min. heating output (0-100%)
Maximum temperature setpoint setting
F16
00 = 85°C - 01 = 45°C
Pump overrun time
F17
(01-240 minutes)
Minimum burner pause
F18
in central heating mode - 00=10 seconds
F19
Manufacturer information
F20
Manufacturer information
Anti-legionella function
F21
00 = Disabled - 01 = Enabled
F22
Manufacturer information
F23
Maximum D.H.W. setpoint
F24
Manufacturer information
F25
Lack of water safety device
F26...F29
Manufacturer information (read-only parameters)
F30
Manufacturer information
F31
Manufacturer information
F34...F41
Diagnostics (See SERVICE Instructions)
Final
Calibration function activation (See SERVICE
parameter
Instructions)
WARNING:
do not modify the values of the "Manufacturer information" parameters.
INSTRUCTIONS PERTAINING TO THE INSTALLER
19. PARAMETERS SETTING
-
buttons together for at least 6 seconds. When the function is activated,
42
Default value
240 i
20
00 O 01
00
02
04
00
00
100
100
00
00
03
03
07
--
00
00
60
35
00
--
10
30
--
00
7217395.01