Press the
domestic hot water buttons to display the following instantaneous information:
A00:
domestic hot water temperature value (°C);
A01:
outside temperature (with external probe sensor connected);
A02:
modulatine current value (100% = 230 mA METANE - 100% = 310 mA GPL);
A03:
power range level value (%) - see parameter F13 (section 19);
A04:
temperature setpoint value (°C);
A05:
central heating flow temperature value (°C);
A06:
flow water value (l/min x 10);
A07:
flame signal value (8-100%).
Note: lines A08 and A09 are not used.
This function is active for 3 minutes. To exit the function, press
Note: the resetting operation is available only for 5 consecutive attempts, after which the RESET function is disabled and
the gas boiler remains blocked.
To carry out a new RESET attempt, proceed as follows:
• press the
button for at least 2 seconds;
• reset the boiler pressing the
• press the
button for at least 2 seconds as describe in section 3.2.
See section 9 for error codes and anomalies description.
For more detailed technical information, please consult the "SERVICE INSTRUCTIONS".
INSTRUCTIONS PERTAINING TO THE INSTALLER
18.3 ANOMALIES DISPLAY
button for at least 2 seconds, the display shows

18.4 ADDITIONAL INFORMATION

41
button as described in section 3.2.
"OFF";.
7217395.01
- en