DOWNLOAD INFORMATION ( ✱ 94, ✱ 95)
✱ 94
DOWNLOAD PHONE No.
✱ 95
RING COUNT FOR DOWNLOADING
PAGER OPTIONS 160-172
✱ 160 PAGER 1 PHONE No.
✱ 161 PAGER 1 CHARACTERS
✱ 162 PAGER 1 REPORTING OPTIONS
✱ 163 PAGER 2 PHONE No.
✱ 164 PAGER 2 CHARACTERS
✱ 165 PAGER 2 REPORTING OPTIONS
✱ 166 PAGER 3 PHONE No.
✱ 167 PAGER 3 CHARACTERS
✱ 168 PAGER 3 REPORTING OPTIONS
✱ 169 PAGER 4 PHONE No.
✱ 170 PAGER 4 CHARACTERS
✱ 171 PAGER 4 REPORTING OPTIONS
✱ 172 PAGER DELAY OPTION FOR ALARMS

REPORTING OPTIONS

✱ 174 CLEAN ME REPORTING OPTIONS
(for ESL smoke detectors)
✱ 177 DEVICE DURATION 1, 2
(used in *80 Menu mode-Device Actions 5/6)
|
|
|
|
|
|
|
Enter up to 20 digits, 0–9; #+11 for ' ✱ '; #+12 for '#'; #+13 for a 2-second pause. Do not fill unused
spaces. If fewer than 20 digits, exit field by pressing ✱ (and press 95, if entering next field). To clear
entries from field, press ✱ 94 ✱ . UL: downloading may be performed only if a technician is at the site.
[15]
NOTE: Do not enter "0" if using
4285/4286 Phone Module.
|
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
|
|
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
Part. 1 Part. 2 common
[0,0,0]
|
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
|
|
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
Part. 1 Part. 2 common
|
|
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
|
|
|
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
0,0,0]
Part. 1 Part. 2 common
|
|
|
|
|
|
|
|
Enter up to 20 digits. 0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
|
|
|
|
Enter the optional prefix characters, up to 16 digits.
0–9; #+11 = ' ✱ '; #+12 = '#'; #+13 = 2-second pause.
[0,0,0]
Part. 1 Part. 2 common
[3]
[0]
[0] [0]
1
2
– 6 –
|
|
|
|
|
|
|
|
0 = Disable Station Initiated Download;
1–14 = number of rings (1–9, # +10 =10, # +11 =11,
# +12 =12, # +13 =13, # +14 =14);
15 = answering machine defeat (# +15 =15).
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
For each partition, select from the following options:
0 = no reports sent
1 = Open/closes all users
4 = All alarms and troubles
5 = All alarms / troubles, and open/closes for all users
12 = Alarms / troubles for zones entered in zone list 9
13 = Alarms / troubles for zones entered in zone list 9,
and open\closes for all users
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
See field *162 for reporting options. Select for each
[0,0,0]
partition (use zone list 10 if using options 12 or 13).
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
See field *162 for reporting options. Select for each
partition (use zone list 11 if using options 12 or 13).
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
See field *162 for reporting options. Select for each
partition (use zone list 12 if using options 12 or 13).
0 = none, 1 = 1 minute, 2 = 2 minutes, 3 = 3 minutes
This delay is for ALL pagers in the system.
NOTE: The delay does not reset for new alarms
occurring while an existing pager delay is in progress.
0 = disable; 1 = Clean Me signal reports;
Note: If Clean Me is enabled, you must enter "3" in
field ✱56 programming for zone 1 response time.
0 = 15 seconds
1 = 30 seconds
2 = 45 seconds
3 = 60 seconds
4 = 90 seconds
5 = 2 minutes
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
6 = 2-1/2 min
#+11 = 7 min
7 = 3 min
#+12 = 8 min
8 = 4 min
#+13 = 10 min
9 = 5 min
#+14 = 12 min
#+10 = 6 min
#+15 = 15 min