Series Transmitter Input Loop Identification; Table Of Device Addresses - Honeywell Ademco VISTA-20PCN Programming Manual

Hide thumbs Also See for Ademco VISTA-20PCN:
Table of Contents

Advertisement

5800 Series Transmitter Input Loop Identification

• All of the transmitters illustrated below have one or more unique factory assigned input (loop) ID codes. Each
of the inputs requires its own programming zone (e.g., a 5804's four inputs require four programming zones).
• Transmitter inputs entered as:
"RF" (Supervised RF) Type send periodic check-in
signals, as well as fault, restore and low battery signals.
The transmitter must remain within the receiver's range.
"UR" (Unsupervised RF) Type send all the signals that
the "RF" Type does, but the control does not supervise
the check-in signals. The transmitter may, therefore, be
carried off-premises.
"BR" (Unsupervised Button RF) Type only send fault
signals. They do not send restore or check-in signals.
They will indicate a low battery condition when tested or
activated normally. The transmitter may be carried off-
premises.
Note: For information on any transmitter not shown
above, refer to the instructions accompanying that
transmitter for details regarding loop numbers, etc .
UL NOTE: The 5802MN, 5802MN2, 5804,
5804BD, 5814, 5816TEMP, 5819,
5819WHS & BRS, 5827BD, and 5850
transmitters are not intended for use
in UL installations

Table of Device Addresses

††
Address
Report
00
100
03
103
04
104
07
107
08
108
09
109
10
110
11
111
12
112
13
113
14
114
15
115
16
n/a
17
n/a
18
n/a
19
n/a
20
n/a
21
n/a
22
n/a
23
n/a
28
n/a
† These module addresses apply to VISTA-20P only.
††
Addressable devices are identified by "1" plus the device address when reporting. Enter report code for zone 91 to enable
addressable device reporting (default = reports enabled). See field *199 for addressable device (ECP) 3-digit/2-digit identification
touchpad display options.
Device
RF Receiver
Long Range Radio
4286 Voice Module
Zone Expanders (4219/4229):
module 1 zones 09 - 16
module 2 zones 17 - 24
module 3 zones 25 - 32
module 4 zones 33 - 40
module 5 zones 41 - 48
Relay Modules (4204):
module 1
module 2
module 3
module 4
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
5800TM Module
LOOP 3
LOOP 2
LOOP 1
LOOP 4
YOU MUST
ENROLL THIS
BUTTON
ENROLL AS "UR" OR "RF"
5 8 0 1
ENROLL AS "UR" OR "RF"
LOOP 3
YOU MUST
ENROLL THIS
BUTTON
LOOP 2
LOOP 4
LOOP 1
5 8 0 4
ENROLL
AS "BR"
LOOP 3
• •
• •
5 8 0 4 B D
ENROLL AS "BR"
LOOP
1
5809
ENROLL AS "RF"
LOOP
1
5808
5 8 1 6
ENROLL AS "RF"
ENROLL AS "RF"
Programmed by...
*56 zone programming: input device type entry
automatic if output to long range radio field *29 enabled
automatic if phone module access code field *28 enabled
*56 zone programming: input device type entry, then:
• automatic if zone no. 9-16 entered as AW type or relay assigned
• automatic if zone no. 17-24 entered as AW type or relay assigned
• automatic if zone no. 25-32 entered as AW type or relay assigned
• automatic if zone no. 33-40 entered as AW type or relay assigned
• automatic if zone no. 41-48 entered as AW type or relay assigned
*79 output device programming: device address prompt:
• entered at device address prompt
• entered at device address prompt
• entered at device address prompt
• entered at device address prompt
data filed programming as listed below:
• always enabled for partition 1, all sounds enabled.
• data field *190
• data field *191
• data field *192
• data field *193
• data field *194
• data field *195
• data field *196
automatic
– 15 –
LOOP 2
LOOP
(REED)
2
(REED)
LOOP 1
(TERMINALS)
LOOP
1
ALTERNATE
5 8 1 6 M N
POSITION
ENROLL AS "RF"
FOR LOOP2
5 8 0 2 M N
LOOP
LOOP
2
(REED)
LOOP 1
(REED)
(TERMINALS)
LOOP 2
LOOP 3
YOU MUST
(TERMINALS)
ENROLL THIS
LOOP 3
BUTTON
(TERMINALS)
5 8 1 9
LOOP 4
ENROLL AS "RF"
LOOP 1
• •
• •
SET
5 8 2 7
HOUSE
SET HOUSE CODE
CODE
LOOP
2
(REED)
LOOP 1
(TERMINALS)
(Green)
(Red)
(Yellow)
5 8 5 0 ( G B D )
ENROLL AS "RF"
LOOP
1
(PRIMARY)
2
(AUX. CENTER)
3
(AUX. RIGHT)
5 8 1 7
ENROLL AS "RF"
2
LOOP 1
(INTERNAL
SHOCK
SENSOR)
5 8 1 9 S ( W H S & B R S )
ENROLL AS "RF"
5 8 2 7 B D
SET HOUSE CODE
LOOP
1
(MOTION)
5 8 9 0
ENROLL AS "RF"

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ademco vista-20pAdemco vista-15pAdemco vista-15pcn

Table of Contents