Locating Your Gas Fireplace; Manufactured Mobile Home Additional Requirements; Heatwave Duct System (Optional); Heat Release Kit (Optional) - FPI P36D-NG1 Owners & Installation Manual

Direct vent gas fireplace
Hide thumbs Also See for P36D-NG1:
Table of Contents

Advertisement

This includes:
1) Clocking the appliance to ensure the correct
fi ring rate (rate noted on label 30,000 Btu/h)
after burning appliance for 15 minutes.
2) If required, adjusting the primary air to ensure
that the fl ame does not carbon. First allow
the unit to burn for 15-20 min. to stabilize.
CAUTION: Any alteration to the product that
causes sooting or carboning that results
in damage is not the responsibility of the
manufacturer.
LOCATING YOUR
GAS FIREPLACE
1) When selecting a location for your fi replace,
ensure that the clearances outlined on this
page are met.
2) P r o v i d e a d e q u a t e c l e a r a n c e s f o r
servicing.
3) The appliance must be installed on a fl at,
solid, continuous surface (e.g. wood, metal,
concrete). This may be the fl oor, or raised up
on a platform to enhance its visual impact.
If the appliance is going to be installed
on carpeting, combustible linoleum tile or
other combustible material other than wood
fl ooring, the appliance must be installed on
a metal or wood panel extending the full
width and depth of the appliance.
4) The P36D-1 Direct Vent Gas Fireplace
can be installed in a recessed position or
framed out into the room as in A, B, C, D.
See Diagram 1.
FPI P36D-1 Zero Clearance Direct Vent Gas Fireplace
A)
Flat on Wall
B)
Flat on Wall Corner
C)
Recessed into Wall/Alcove
D)
Corner
5) This appliance is Listed for bedroom
installations when used with a Listed Millivolt
Thermostat. Some areas may have further
requirements, check local codes before
installation.
6) The P36D-1 Direct Vent Gas Fireplace is
approved for alcove installations, which meet
the clearances listed on the next page.
7) We recommend that you plan your installation
on paper using exact measurements for
clearances and floor protection before
actually installing this appliance. Have a
qualifi ed inspector, dealer, or installer review
your plans before installation.
Note: For vent terminations see "Exterior
Vent Termination Location" section.
INSTALLATION
MANUFACTURED
MOBILE HOME
ADDITIONAL
REQUIREMENTS
1) Ensure that structural members are not cut
or weakened during installation.
2) Ensure proper grounding using the #8
ground lug provided. See "Wiring Diagram"
section.
Diagram 1
HEATWAVE
DUCT SYSTEM
(OPTIONAL)
The HeatWave Air Duct Kit increases the
effectiveness of your fi replace by dispersing
warm air from the fi replace to remote locations in
the same room or other rooms in your home.
Up to two kits may be installed on the fi replace.
Please Note: Only 1 HeatWave kit may be
operated at one time. This includes the internal
blower option as well.
HEAT RELEASE KIT
(OPTIONAL)
The Heat Release Kit expels warm air from
the fi replace to the outside of the building,
allowing the fi replace to be operated with less
heat entering the room. The kit may be used
on either the left or right side.
#946-556
#946-570
9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

P36d-lp1

Table of Contents