1
Before you begin installing the fan, S witch
power off at Service panel and lock service dis -
connecting means to prevent power from being
switched on accidentally. When the service dis -
connecting means cannot be lock ed, securely
fasten a prominent warning device, such as a
tag, to the service panel.
4
Install downrod to canop y and then install y oke
cover to downrod. Thread wires and safet y
cable through downrod
7
Check the motor for plastic shipping sta -
bilizer tabs and remove them if they are
present.
© 2011 Monte Carlo Fan Company
2
Before installing this fan mak e sure the outlet bo x is
properly installed to the house structure. T o reduce
the risk of fire, electric shock, or personal injury ,
mount to outlet box or supporting system acceptable
for fan support. (Mounting must support at least 35
lbs.)
5
Loosen set screws with locking nuts and
remove keeper from pin and then pin from
yoke for downrod (see inset).
8
Hang assembled fan from the mounting br acket
installed to ceiling in previous steps. Mak e sure the
fan is hanging straight. Rotate fan until the tab on
the Mounting bracket engages the slot on the
Downrod Ball. This must be done to prev ent the fan
body from rotating when the blades are in motion.
3
3
Use metal outlet box suitable for fan support
(must support 35 lbs). Before attaching fan to
outlet box, ensure the outlet bo x is securley
fastened by at least two points to a structur al
ceiling member ( a loose bo x will cause the fan
to wabble). Use only the screws provided
with the outlet box.
6
Install downrod with canop y and yoke covers
into yoke. Align hole in downrod and y oke,
push pin through and replace k eeper. Tighten
set screws and locking nuts (see inset).
9

Safety cable installation

Safety Cable
Lag Screw
safety
cable
washer
lock
3" lag
washer
screw
For Canadian installation and for USA fan and light
kit combinations over 35 lbs, in both flush and
downrod modes the safety cable must be installed
into the house structure beams using 3" lag
screws, washers and lock washers provided. Make
sure that when the safety cable is fully extended
the lead wires are longer than the cable and no
stress is placed on the lead wires.
Note:If Installing The Secondary Support Safety
Cable in the U.S., Do Not Remove Knockouts In
The Outlet Box.