Removing The Flat Solar Panel - Daikin EKSV21P Installation Manual

Solar panel on-roof installation
Hide thumbs Also See for EKSV21P:
Table of Contents

Advertisement

3
x
Installation
3. Run the silicone-covered sensor cable to
the roof breakthrough (with drip-off
elbow), and secure it to the mounting rail or
connecting pipe by means of cable ties.
4. Inside the roof, connect the silicone cable of the solar panel temperature sensor to the input cable of the solar panel
temperature sensor of the regulating and pump unit (
3.5

Removing the flat solar panel

Solar panel dismantling is carried out basically in the reverse sequence to the solar panel assembly.
If the flat solar panels are to be separated,
the connection elbows or expansion joints
must first be released as follows:
1. Press the retaining clamps out of the
engagement positions and pull off
(fig. 3-57 and fig. 3-58).
2. Pull off the connection elbows
(fig. 3-58).
Installation instructions
34
Fig. 3-56
CAUTION!
Moisture can damage the temperature sensor.
• When securing the cable, make sure that no rainwater can run down the cable to the sensor well (installing
with drip-off elbow see fig. 3-57).
WARNING!
Live parts can cause an electric shock on contact and cause life-threatening burns and injuries.
• Before beginning removal work, disconnect all components that are electrically linked to the solar system
(heat generator, solar control, etc.) from the power supply (switch off fuse, main switch) and secure
against unintentional restart.
• Comply with the relevant safety at work regulations.
WARNING!
Danger of burns from hot solar panel couplings and hot solar panel frame.
• Do not touch hot parts.
• Wear protective gloves.
Fig. 3-57
Work step 3 (shown on the Drain-Back system
EKSRPS3 or
EKSR3PA).
Work step 1
Fig. 3-58
)
Work step 2
EKSV21P/EKSV26P/EKSH26P
Solar panels on-roof installation
008.1618444_00 – 12/2012

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eksv26pEksh26p

Table of Contents