Pressurised solar system
Hide thumbs Also See for EKSV21P:

Advertisement

Planning and installation
instructions
DAIKIN Pressurised solar system
Planning and installation instructions
English
DAIKIN Pressurised solar system
EKSV21P
EKSV26P
EKSH26P
Solar assembly packages

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EKSV21P and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Daikin EKSV21P

  • Page 1 Planning and installation instructions DAIKIN Pressurised solar system Planning and installation instructions English DAIKIN Pressurised solar system EKSV21P EKSV26P EKSH26P Solar assembly packages...
  • Page 2: Table Of Contents

    List of keywords ..... 31 Planning and installation instructions EKSV21P + EKSV26P + EKSH26P DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 3: General Information

    ● Work on the DAIKIN Solar system (such as hydraulic and electrical connection and initial start-up) is only to be carried out by persons who are authorised and who have success-...
  • Page 4: Safety

    2.2 Avoiding danger DANGER! DAIKIN solar installations are state of the art and Draws attention to imminent danger. are built to meet all recognised technical require- ments. However, improper use may result in...
  • Page 5: Instructions For Operating Safety

    (switch off main switch, remove fuse) and secure against unintentional restart. ● Equipment covers and service panels must be replaced as soon as the work is completed. EKSV21P + EKSV26P + EKSH26P Planning and installation instructions DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 6: Product Description

    Solar tank with integrated interior heat pump unit EKHWP Energy storage tank EKHWP…PB Fig. 3-1 Standard design of a DAIKIN Solar system (DAIKIN recommends a two-way connection) Planning and installation instructions EKSV21P + EKSV26P + EKSH26P DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 7: Brief Description

    3.2 Brief description 3.3 System components for pressurised solar systems The DAIKIN solar system is a thermal solar system for supplying hot water for consumption and solar support. 3.3.1 System components for all systems The pressurised solar system must only be used with...
  • Page 8 For connecting the CON 15P16 pressurised solar pipe CON CP20 For connecting the CON 15P20 pressurised solar pipe Fig. 3-6 CON CP16 / CON CP20 Planning and installation instructions EKSV21P + EKSV26P + EKSH26P DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 9 Fig. 3-9 CORACON SOL 5F (8x) (12x) Diaphragm expansion vessel MAG S12 for pressurised solar systems up to maximum 2x EKSV21P / (5x) EKSV26P solar panels MAG S25 for pressurised solar systems up to maximum 3 solar panels MAG S35...
  • Page 10: System Components For Roof-Mounted Systems (Adm)

    Connecting pipe Cu Ø 22 mm (1 m) FIX WD for corrugated roofing Fig. 3-15 CON LCP 4 ( x) 12h Mounting profile beam Quick instructions Fig. 3-13 FIX WD Planning and installation instructions EKSV21P + EKSV26P + EKSH26P DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 11: System Components For In-Roof Systems (Idm)

    Product description 3.3.3 System components for in-roof systems (IDM) In-roof mounting packs Expansion package IE V21P for each further EKSV21P flat solar panel (3 to 5) Basic package IB V21P for two EKSV21P flat solar panels Expansion package IE V26P...
  • Page 12 Single terminal block with equipotential bonding terminal Single terminal block HT-Armaflex Ø 22 x 13 UV-resistant (1 m) Connecting pipe Cu Ø 22 mm (1 m) Fig. 3-19 CON LCP Planning and installation instructions EKSV21P + EKSV26P + EKSH26P DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 13: System Components For Flat Roof Systems (Fdm)

    Hexagon nut M8 Hexagon nut M8 with locking serration Washer Round head screw M8 Quick instructions Fig. 3-21 Flat roof frame, basic package FB V26P EKSV21P + EKSV26P + EKSH26P Planning and installation instructions DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 14 Washer Round head screw M8 Fig. 3-22 Flat roof frame, expansion package FE V26P Quick instructions Fig. 3-23 Flat roof frame, basic package FB H26P Planning and installation instructions EKSV21P + EKSV26P + EKSH26P DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 15 Hexagon screw M8 Hexagon nut M8 Hexagon nut M8 with locking serration Washer Round head screw M8 Fig. 3-24 Flat roof frame, expansion package FE H26P EKSV21P + EKSV26P + EKSH26P Planning and installation instructions DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 16: Installation

    4.1.1 Transport All assembly information for the sub-construction or the roof integration of the DAIKIN Solar flat solar panels are given in the respective quick instructions which accompany the CAUTION! ● roof-mounted assembly packages ●...
  • Page 17: System Layouts

    Installation 4.2 System layouts Collector connector Mounting rail DAIKIN solar systems are usually built according to one of the fol- Solar panel securing clips lowing system concepts. Solar panel Solar panel connecting elbow return flow 4.2.1 Parallel connection Solar panel connecting elbow inflow...
  • Page 18: Laying The Connecting Pipe

    25 m – 25 m – 25 m Tab. 4-2 Maximum lengths of the DAIKIN connecting pipes Notes on the roof penetration of the connecting pipe CAUTION! Leaking vapour barriers can lead to building Fig. 4-4 Steps 5a and 5b damage.
  • Page 19: Mounting The Flat Solar Panels

    The solar panel mounting and the hydraulic connection is only carried out after installation of the requisite sub- construction. All assembly information for the sub- construction or the roof integration of the DAIKIN Solar flat solar panels are given in the respective quick instructions which accompany the ●...
  • Page 20 CAUTION! If the retaining clamps do not click in place au- dibly, the DAIKIN Solar system can develop leaks and thus restrict operational safety. Reasons for the retaining clamps not engaging: ● Flat solar panels not completely pushed together.
  • Page 21: Connecting The Pressurised Solar System Hydraulically

    1. Before installing the plug connections, check the proper seat- ing of the holding clamps and inspect the O-rings for damage. ZB Solar Fig. 4-13 Step 1 EKSV21P + EKSV26P + EKSH26P Planning and installation instructions DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 22 5. Slide the heat insulation hoses onto the connection pipes or solar panel connecting elbows and cut to the required length. Fig. 4-19 Step 7 Fig. 4-17 Step 5 Planning and installation instructions EKSV21P + EKSV26P + EKSH26P DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 23: Installing The Equipotential Bonding Terminal

    1. Remove the sensor plugs at the top edge of the solar panel. Fig. 4-22 Work step 3 EKSV21P + EKSV26P + EKSH26P Planning and installation instructions DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 24: Start-Up And Taking Out Of Operation

    4. Check all connection points and joints of the solar system circuit for leaks. The DAIKIN solar system can be temporarily shut down by dis- 5. Then determine and set the system pressure in accordance connecting the mains plug from the power supply.
  • Page 25 Start-up and taking out of operation ● Drain the DAIKIN solar system (collect the solar system fluid and dispose of it properly) and dismantle in reverse order according to the installation manual (chapter 4 "Installation"). ● Properly dispose of the DAIKIN solar system.
  • Page 26: Technical Data

    Gross surface area 2.01 2.60 Aperture surface area 1.80 2.36 Absorber surface area 1.80 2.36 Heat insulation Material – Mineral wool Thermal conductivity W/(m K) 0.037 Thickness Planning and installation instructions EKSV21P + EKSV26P + EKSH26P DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 27 *) with regard to the gross surface area of the solar panel / solar panel filled with fluid Tab. 6-2 Technical data, flat solar panel 25,0 EKSV21P EKSV26P 20,0 EKSH26P 15,0 10,0 m / L/h Fig. 6-1 Hydraulic resistance, flat solar panels EKSV21P + EKSV26P + EKSH26P Planning and installation instructions DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 28: Roof-Mounted System - Max. Permissible Snow Load (Roof-Mounted) As Per En 1991-1-3

    With a rafter spacing of 1000 mm, a roof gradient of 30° and a building height < 10 m * At a rafter spacing of 650 mm, a roof gradient of 30° and a building height < 10 m * For detailed execution information, contact DAIKIN Service does not apply to exempted regions stated in EN 1991-1-3 Tab.
  • Page 29: Flat Roof System - Shading

    2.53 2.67 2.71 2.72 3.43 3.71 3.89 3.93 3.94 2.23 2.41 2.53 2.55 2.56 Tab. 6-5 Measurement z with shading α α Fig. 6-2 Shading EKSV21P + EKSV26P + EKSH26P Planning and installation instructions DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 30: Notes

    Notes Notes Planning and installation instructions EKSV21P + EKSV26P + EKSH26P DAIKIN Solar P-SYS 008.1629544_01 – 12/2016...
  • Page 31: List Of Keywords

    Sensor plugs ....23 Series connection ....17 EKSV21P + EKSV26P + EKSH26P Planning and installation instructions DAIKIN Solar P-SYS 008.1629544_01 –...
  • Page 32 008.1629544_01 12/2016...

This manual is also suitable for:

Eksv26pEksh26p

Table of Contents