Checking the Leak Detector

The leak detector system is designed to assist in early
detection of hydraulic oil system leaks. If the oil level in the
main hydraulic reservoir, is lowered by 118-177 ml (4 to 6
ounces), the float switch in the tank will close. After a one
second delay, the alarm will sound, alerting the operator
(Figure 30). Expansion of oil, due to normal heating during
machine operation, will cause the oil to transfer into the
auxiliary oil reservoir. The oil is allowed to return to the main
tank when the ignition switch is turned off.
Before start (oil cold)
1. Breather cap
2. Filler neck
3. Overflow tube
4. Sight window
G020735
Figure 28
5. Solenoid return valve open
6. Float raised switch open
7. No sound
8. Fluid level (cold)
Normal operation (oil warm)
1. Solenoid return valve
closed
2. Float raised switch open
1. Float down switch closed
Fluid level down 118–177
ml (4 to 6 ounces)
2. Warning buzzer
Checking the Leak Detector System
Operation
1. Move the ignition switch to the On position. Do not
start the engine.
2. Remove the hydraulic tank cap and strainer from the
neck of the tank.
3. Insert a clean rod or screwdriver into the tank neck and
gently push down on the switch float (Figure 31). The
alarm should sound after the one-second delay.
26
G020736
Figure 29
3. Warning buzzer
4. Fluid level (warm)
G020737
Figure 30
Leak Alert!
3. Fluid level (warm)