Remove Of Transformer; Removal Of The Igniter; Removal Of The Manifold & Burner Unit - Rinnai REU-V1616WF Service Manual

High capacity continuous flow gas hot water system
Table of Contents

Advertisement

4)

Remove of Transformer

a. Remove the EMC sub board. (Refer 3)
b. Disconnect earth wire from the PCB (1 screw).
c. Disconnect harness from the terminal. (2 screws).
d. Remove the transformer (2 screws).
e. Remove the transformer from bracket (2 screws)
Transformer
Infinity REU-V1616WF
5)

Removal of the Igniter

a. Remove the igniter (1 screw)
b. Remove the 3 pin connector. (Grey-grey)
c. Remove the high tension lead.
Igniter
6)
Removal of the Manifold & Burner unit.
a. Remove ignition lead (black) and flame rod
(Yellow).
b. Remove the manifold (9 screws + 2 ignition leads).
- 36 -
Issue 1 - 21/11/03 ©Rinnai