8. Connect the signal cable to the RTB Board (03P9249). See the interconnection diagram and
the figure shown below.
9. Attach three EMI cores to the signal cable as shown below.
Antenna unit: RSB-0071-057
XN10A-RSB-0070-064
XN10A-RSB-0073-064
XN12A-RSB-0070-059
XN12A-RSB-0073-059
Lead in
cable here.
EMI core
Run cable along here.
RFC-13
10.Fasten the signal cable with the cable clamp.
11.Undo the stay and close the cover. Securely Fasten the scanner bolts.
Note: When you close the cover, set the gaskets to the grooves in the bottom chassis, then tighten
the bolts.
RTB Board
J821 VH9P
J822 VH2P
J824 NH13P
J823 VH4P
Clamp
Antenna unit chassis, cover opened
Bottom
Chassis
Groove
Gasket
Antenna Bolt
Torque : 9.8 ±0.1 Nm
Antenna unit: RSB-0071-057A
XN10A-RSB-0070-064A
XN10A-RSB-0073-064A
XN12A-RSB-0070-059A
XN12A-RSB-0073-059A
Lead in
cable here.
EMI core
RFC-13
Run cable along here.
RTB Board
J821 VH9P
J822 VH2P
J824 NH13P
J823 VH4P
Clamp
1-17