Flange Back Check - Sony DSC-S70 Service Manual

Hide thumbs Also See for DSC-S70:
Table of Contents

Advertisement

2. Flange Back Check

Mode
Subject
Measurement Point
Measuring Instrument
Specified value
Checking method:
1)
Place the Siemens star 2.0 m from the front of the lens.
2)
To open the IRIS, decrease the luminous intensity to the Si-
emens star up to a point before noise appear on the image.
3)
Select page: 0, address: 01, and set data: 01.
4)
Select page: 5, address: F1, and set data: FF.
5)
Select page: D, address: 63, set data: 40, and press the PAUSE
button of the adjusting remote commander.
6)
Perform " Data setting during camera system adjustment".
(Refer to page 5-13)
7)
Shoot the Siemens star with the zoom TELE end.
8)
Turn on the auto focus.
9)
Check that the lens is focused.
10) Select page: 6, address: 2C, and set data: 01.
11) While observe the TV monitor, change the zoom to the WIDE
end and check that the lens is focused.
Processing after completion of adjustment:
1)
Select page: 6, address: 2C, and set data: 00.
2)
Select page: 5, address: F1, and set data: 00.
3)
Select page: D, address: 63, set data: 00, and press the PAUSE
button of the adjusting remote commander.
4)
Release the data setting performed at step 6).
(Refer to page 5-13)
5)
Select page: 0, address: 01, and set data: 00.
STILL
Siemens star
(2.0 m from the front of the lens)
(Luminance: approx. 200 lux)
Check operation on TV monitor
Focused at the TELE end and
WIDE end
5-15