If Thermal Protection Mode Step 2 is reached, the internal temperature needs to first decrease
back to the Step 1 temperature and then decrease further to the value required to disable
Thermal Protection Mode 1.
Example of Thermal Protection Mode for an ET4201L Monitor with 100% Brightness:
At Step 1: OSD = 60, Brightness = 80%
Normal operation returns if OSD can maintain 55°C or lower temperature for five
minutes.
At Step 2: OSD = 65, Brightness = 72%
Return to Step 1 if OSD can maintain 60°C or lower temperature for five minutes.
If the monitors internal temperature continues to rise, the monitor will shut off at OSD = 70°C
Table Top Mode
Requirements:
1. The Table Top Mode function on the OSD must be enabled if the unit is placed in table
top orientation.
2. Cooling methods must be put in place to ensure that the air temperature beneath the
monitor does not exceed the operating specifications. Consult chapter 7 for operating
temperature specifications.
Note: The warranty will be void if failure occurs to the monitor in table top mode orientation and
the Table Top Mode function is not enabled without adequate cooling methods installed.
When the monitor is in Table top mode, the Thermal Protection steps are different. These OSD
values are stated in the table below.
Monitor Size
ET32/4201L
ET5501L/ET5501LT
ET7001L/ET7001LT
Monitor Size
ET32/4201L
ET5501L/ET5501LT
ET7001L/ET7001LT
Thermal
Protection Mode
Protection Mode
Enabled (°C)
Step 1
60
57
59
Thermal
Protection
Mode Step
1 Disabled
(°C)
55
53
45
Thermal
Protection Mode
Enabled (°C)
Step 2
65
61
64
Thermal
Auto Shut Off
Temperature (°C)
Enabled (°C)
Step 3
70
n/a
69
User Manual: Interactive Digital Signage
SW601990 Rev L, Page 25 of 37
75
65
74