ORIFICE CONVERSION
1. FROM NATURAL GAS TO LP/PROPANEGAS:
2. FROM LP/PROPANEGAS TO NATURALGAS:
a. Change the appliance pressure regulator from
a. ChangetheappliancepressureregulatorfromLPto
natural to LP setting. (Seefigure 3).
natural setting. (Seefigure 3).
b. Screw the burner orifice hoods down tight against
b. Screw the burner orifice hoods awayfrom the pins.
the pins. (See figure 4B). Use care to not over
(Seefigure 4A). Approximately1 1/2 to 2 turns.
tighten.Over tighteningcandamagethe coaxialpin
inside the orifice hood.
c. Adjust burner air shutter to the widest openingthat
will not cause the flame to lift or blow off the burner
c. Adjust burner air shutterto the widest openingthat
when cold.
will not causethe flame to lift or blow off the burner
when cold.
NOTE: Correctly adjusted sealed burners, the
flame will lift or blow without a pot over the burner.
NOTE: Correctlyadjustedsealedburners,can have
These should be adjusted with a pot in place.
flames that will lift or blow without a pot over the
burner. These should be adjusted with a pot in
place.
ORI
SERVICE - PARTS INFORMATION
FICE
,_T _ 9219-,,3-o
WHEN YOUR RANGE REQUIRES SERVICE OR
REPLACEMENTPARTS, CONTACTYOUR DEALEROR
FIGURE4A
FIGURE4B
AUTHORIZED SERVICE AGENCY. PLEASE GIVE THE
NATURALGAS
LP GAS
COMPLETE MODEL AND SERIAL NUMBERS OF THE
SETTING
SETTING
RANGE WHICH IS LOCATED ON THE RANGE MODEL
NUMBER PLATE.