INSTRUCTIONS FOR POSITIONING THE UNIT
- The geared motor unit has been assembled in
the factory to be fitted to the LEFT SIDE of the
gate (internal view). To install the motor to the
RIGHT of the gate set dip 8 of the dip-switch
"DS1" (fig. 3) to "ON".
MANUAL MANOEUVRE WITH THE MOTOR RELEASED
Manual release is to be carried out with the motor Stopped. To release
the gate use the manual release key supplied with the unit. The key
should be kept in an easily accessible place.
To release the unit
1. Rotate the lock protection disk on the
release knob, insert the key and rotate it
half a turn anticlockwise. The knob is now
free and can be released.
2. Rotate the knob through 90° clockwise. The
gears are now released and the gate can be
moved manually.
To relock the unit
1. Rotate the handle anticlockwise and move it back to the blocked
position.
2. Rearm the gears:
- electrically by giving an opening or closing command;
- by slightly moving the gate
3. Rotate the key clockwise and relock the handle.
Once the system has been reset store the key in a safe place.
Attention! Never use the manual release mechanism while
the gate is in operation. If you release the gate and then give
a movement command the following symbol will appear
rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
on the display
9
A
ELECTRONIC PROGRAMMER
Electronic programmer for a dc motor with an incorporated radio
receiver card, which allows the memorisation of 300 user codes (see
"remote control" page 20). The "rolling code" type decoder uses 433.92
MHz series transmitters.
The motor rotation speed is electronically controlled, starting slowly
and increasing in speed; the speed is reduced as it nears the travel
limit so as to enable a controlled smooth stop.
LA: 1:2
Programming is carried out using one button and allows you to set the
Description :
Prodotti Technocity
ng number :
DI0243
Sblocco carter
ct Code :
SL1524
system, the current sensor and the entire gate travel distance.
:
P.J.Heath
Date :
07-02-2002
N ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
The logic carries out position control using an encoder.
The intervention of the anticrush/antidrag sensor during the closing
and opening stages causes a brief (10 cm) travel direction inversion
then a block.
7
ON
All rights reserved. Unauthorised copying or use of the information contained in this document is punishable by law
SCALA: 1:2
Description :
Drawing number :
DI0242
Sblocco motore
.
Product Code :
SL1524
Draft :
P.J.Heath
Date :
07-02-2002
CARDIN ELETTRONICA S.p.A - 31020 San Vendemiano (TV) Italy - via Raffaello, 36 Tel: 0438/401818 Fax: 0438/401831
Access to the electronic card
Attention! Before opening the cover make
sure that the power has been switched off
at the mains.
To access the motor loosen the two screws
"A" positioned on either end of the cover as
indicated in figure 9.
• After having installed the device, and before powering up the
programmer, release the gate (manual release mechanism) and
move it manually, checking that it moves smoothly and has no
unusual points of resistance.
• The programmer can activate the motor automatically. This is
indicated by the warning lights pre-flashing for 10 seconds, and by
the symbol
ing" on page 19).
• The programmer is fitted with an electrical input monitoring
1 2 3 4 5 6 7 8 9
system, which is used to block the motor in emergency conditions;
however this system is not active during the following stages:
- during the first 5 s of an opening stage starting from completely
closed
- during the first 2 seconds of all other movement stages
- when the battery undercharged
Do not therefore attempt to physically block the door during these
stages, otherwise you may risk blowing the motor circuit protec-
tion fuse "F1".
• If you need to check the status of the fuse "F2", disconnect the
power supply to the programmer; reconnect it only after having
re-inserted the fuse.
• The presence of the electrical input monitoring system does
not exclude the need to install photoelectric cells or other safety
devices which are foreseen by the local standards and regulations
in force.
• The geared motor unit has been assembled in the factory to be
fitted to the left side of the gate. Read the paragraph "instructions
for positioning the unit".
All rights reserved. Unauthorised copying or use of the information contained in t
8
• For the correct operation of the programmer the incorporated
batteries must be in good condition: the programmer will lose the
position of the gate in case of blackouts when the batteries are flat,
the alarm will sound and automatic repositioning will take place .
Check the good working order of the batteries every six months
(see page 21 "battery check").
• Before connecting the appliance make sure that the voltage and
frequency rated on the data plate conform to those of the mains
supply.
• An all pole trip switch with at least 3 mm between the contacts
Prodotti Technocity
must be installed between the unit and the mains supply.
• Don't use cables with aluminium conductors; don't solder the
ends of cables which are to be inserted into the binding posts; use
cables marked T min 85°C and resistant to atmospheric agents.
• The terminal wires must be positioned in such a way that both
the wire and the insulating sheath are tightly fastened (a plastic
jubilee clip is sufficient).
Mains power supply connection
• Connect the control and security device wires.
• Run the mains power supply through the cable clamp located on
the bottom right of the main circuit board and to the separate 3-way
terminal board:
- connect the neutral to binding post N
- connect the earth to binding post
- connect the live to binding post
16
IMPORTANT REMARKS
appearing on the display ("automatic reposition-