Nortel 5000 Series Release Notes page 39

Ethernet routing switch
Hide thumbs Also See for 5000 Series:
Table of Contents

Advertisement

Change Request
Number
Q01911582
Q01904189
Q01900513
Q01897761
Q01895450
Q01895070
Q01893356
Q01865091
Q01440362
Q01909890
Q01921407
Q01929584-01
Q01839477
Copyright © 2008., Nortel Networks
.
Description
After you restart the stack, few dynamic ports may not move to Red and
VoIP VLANs.
When you authenticate IP Phones with non-EAP or ADAC, and then restart
the base unit or the last unit, not all ports may be authenticated after the
restarted unit rejoins the stack.
Workaround: Disable and then enable ADAC on the respective ports.
OSPF hello packets may not be captured on 5530 ports when you use ADST
Mac address based mirroring mode.
When you use Device Manager with IGMP, it may display some incorrect
information in the ActiveQuerier and QuerierPort fields under VLAN,
VLANs, Snoop menu. This is a known issue.
When you authenticate IP Phones using non-EAP and ADAC becomes
operationally disabled, it may take up to 300 seconds (5 mins) until EAP
clears the multihost non-eap-mac table. If this is not desirable, EAP can
be bounced on the respective ports.
After you restart a switch or stack with Fail Open enabled (NSNAS connected
in the network), some devices may show as a green IP in the red VLAN. If you
run the shutdown/ no shutdown command, the ports on stack will resolve
the issue for both PCs and passive devices. Or, you can enter the ipconfig
/release; ipconfig /renew command on the PC command line.
After you restart the stack, some NSNA MAC authenticated devices (in the
green VLAN or green filter) may remain with a red IP although the VLAN is
green. Run the shutdown/ no shutdown command to resolve the issue.
NSNA static MAC authenticated clients may not be re-authenticated on Base
unit after it is restarted.
If you use DHCP relay on multiple hops, Nortel recommends that you
configure the DHCP forward path on all hops to the DHCP server.
If you use a policy to filter a multicast flow with a system classifier with
known-mcast or unknown-mcast options configured, it will only match non-IP
traffic for the Ethernet Routing Switch 5600 Series.
In certain topologies, when you connect multiple PIM routers to the same L2
device, both the DR and non-DR routers may install the same OIF, resulting
in duplicate packets for receivers across the L2 device.
Workaround: Connect only a single PIM router to the L2 device.
When you use Web-based management with an IPv6 address, the response
time may be noticeably slower than when you use Web-based management
with an IPv4 address.
If you unplug an IP phone that is on a call or receives line tone, all of the
other phones on the VoIP VLAN receive UDP packets (30-35 packets/sec)
with the Source Address=BCM and Destination Address=IP-phone of the
removed IP phone. The packet flood lasts 20-25 seconds.
Nortel Ethernet Routing Switch 5000 Series
Release Notes — Release 6.0
NN47200-400 04.01 Standard
6.0 12 December 2008
Known issues 39

Advertisement

Table of Contents
loading

Table of Contents