17) The fan control module (supplied with the fan kit) secures to the fl oor of
the unit with a Velcro pad in the position shown in the drawing. Plug the
fan control module into the outlet in the unit.
6-1/2
18) Plug in the fan power cord to the Fan Control Module into the outlet
marked "Fan". Plug the FCM-COM wire from the remote control wiring
harness into the location on the Fan Control Module marked "COM".
Turn the switch on the Fan Control Module to the ON position. ON is to
the left. The "O" is the off position
46 |
®
Regency Horizon
HZ54E-10 Gas Fireplace
10
FCM
7
RECEIVER
Top View
19) Install the fan air defl ector - it hooks to 2 brackets on to the bottom lip
the unit, to the right of the receiver.
Air defl ector
Bracket
Air defl ector
20) Reverse steps 12 through 1 to fi nish the installation.
TO REMOVE THE FAN
1) Turn the power off.
2) Reverse the above instructions.
Maintenance: The sealed bearings are lubricated, there is no need to lu
bricate them further. (Extra lubricant will cause more lint and dust buildup
- causing the bearings to prematurely fail).
Regular cleaning and vacuuming of the fan area will add to the life of the