3.2 Power Supply Connections

3.2.1 Mains Input

Identification
Mains Power
Live
Live (brown) 240Vac 50Hz
Neutral
Neutral (blue) 240Vac 50Hz
Earth
Earth (Yellow/Green)

3.2.2 Connections to dome

Identification
Umbilical lead to dome
CAM2
White Coax signal (dual camera version only)
GND
White Coax screen (dual camera version only)
CAM1
Black Coax signal
GND
Black Coax screen
RS485 (A)
WHITE
RS485 (B)
ORANGE
+24V
RED
0V
BLACK and Cable screen