Front Panel Leds And Buttons - HP ProLiant ML350 Gen9 Maintenance And Service Manual

Hide thumbs Also See for ProLiant ML350 Gen9:
Table of Contents

Advertisement

Front panel LEDs and buttons

Item
Description
UID button/LED
1
Health LED
2
NIC status LED
3
Power On/Standby button and
4
system power LED
Status
Solid blue = Activated
Flashing blue:
1 flash per second = Remote management or
firmware upgrade in progress
4 flashes per second = iLO manual reboot
sequence initiated
8 flashes per second = iLO manual reboot
sequence in progress
Off = Deactivated
Solid green = Normal
Flashing green (1 flash per second) = iLO is
rebooting
Flashing amber = System degraded
Flashing red (1 flash per second) = System critical
If the health LED indicates a degraded or critical
state, review the system IML
Management
Log" on page 72) or use iLO
iLO" on page 70) to review the system health status.
Solid green = Link to network
Flashing green (1 flash per second) = Network
active
Off = No network activity
Solid green = System on
Flashing green (1 flash per second) = Performing
power on sequence
Solid amber = System in standby
Off = No power present
Facility power is not present, power cord is not
attached, no power supplies are installed, power
supply failure has occurred, or the front I/O cable is
disconnected.
("Integrated
("HPE
Component identification 79