Daikin FHQ35CAVEB Installation Manual page 16

Hide thumbs Also See for FHQ35CAVEB:
Table of Contents

Advertisement

11-1 SETTING WHEN AN OPTIONAL ACCESSORY
IS ATTACHED
• For setting when attaching an optional accessory, refer to the
installation manual attached to the optional accessory.
11-2 WHEN USING WIRELESS REMOTE CONTROL-
LER
• When using a wireless remote controller, it is necessary to
set the wireless remote controller address.
Refer to the installation manual attached to the wireless
remote controller.
11-3 SETTING CEILING HEIGHT (TYPE 100 OR
LESS)
• When installing indoor unit type 35 - 100, specify the SEC-
OND CODE No. in accordance with the ceiling height.
Table 4
Ceiling height (m)
Type
Type
35,50
60,71
2.7
2.7
Standard
or less
or less
2.7 -
2.7 -
High ceiling
3.5
3.5
11-4 SETTING FILTER SIGN
• A message to inform the air filter cleaning time will be indi-
cated on the remote controller.
• Set the SECOND CODE No. shown in the Table 5 according
to the amount of dust or pollution in the room.
• Though the indoor unit is equipped with the long life filter, it is
necessary to periodically clean the filter to avoid clogging of
the filter. Please also explain the set time to the customer.
• The periodical filter cleaning time can be shortened depend-
ing on the environment.
Table 5
Filter hours
Contamination
(long life type)
Approx.
Normal
2500 hrs
More
Approx.
contaminated
1250 hrs
With indication
No indication
* Use "No indication" setting when cleaning indication is not
necessary such as the case of periodical cleaning being car-
ried out.
15
FIRST
SECOND
Mode
CODE
CODE
Type
No.
No.
100
3.8
or less
13 (23)
0
3.8 -
4.3
SECOND
FIRST
Mode No.
CORD
CODE No.
No.
01
0
02
10 (20)
01
3
02
11-5 SETTING FAN SPEED DURING THERMOSTAT
OFF
• Set the fan speed according to the using environment after
consultation with your customer.
Table 6
Setting
Fan operates / stops
during thermo OFF
(Cooling · heating)
Fan speed during
cooling
thermostat OFF
Fan speed during
heating
thermostat OFF
11-6 SETTING NUMBER OF THE CONNECTED
INDOOR UNITS AS SIMULTANEOUS OPERA-
TION SYSTEM
No.
• When using in simultaneous operation system mode, change
the SECOND CODE No. as shown in Table 7.
• When using in simultaneous operation system mode, refer to
01
"SIMULTANEOUS OPERATION SYSTEM INDIVIDUAL
SETTING" section to set master and slave units separately.
02
Table 7
Setting
Pair system (1 unit)
Simultaneous
operation
system (2-unit)
Simultaneous
operation
system (3-unit)
Double twin multi
(4-unit)
11-7 SIMULTANEOUS OPERATION SYSTEM INDI-
VIDUAL SETTING
It is easier if the optional remote controller is used when setting
the slave unit.
< Procedure >
• Perform the following procedure when setting the master and
slave unit separately.
• "
" in the tables indicates factory settings.
(Note) The "Mode No." is set on a group basis. To individually
set a Mode No. for each indoor unit or confirm the set-
tings, set the Mode No. in the parenthesis.
(1) Change the SECOND CODE No. to "02", individual setting,
so that the slave unit can be individually set.
Table 8
Setting
Unified setting
Individual setting
(2) Perform field setting (Refer to 11-1 to 11-5) for the master
unit.
(3) Turn off the main power supply switch after (2) is finished.
(4) Detach remote controller from the master unit and connect
it to the slave unit.
FIRST
Mode No.
CODE No.
Operates
11 (21)
2
Stops
(Extra low)
12 (22)
6
Setting
(Extra low)
12 (22)
3
Setting
FIRST
Mode No.
CODE No.
11 (21)
0
FIRST
Mode No.
CODE No.
11 (21)
1
SECOND
CORD No.
01
02
01
02
01
02
SECOND
CODE No.
01
02
03
04
SECOND
CODE No.
01
02
English