Download Print this page

ATTO Technology ATTO FibreBridge 2350C Specification Sheet page 2

Atto technology atto fibrebridge specification sheet
Hide thumbs Also See for ATTO FibreBridge 2350C:

Advertisement

attotech.com
Fibre Channel and SCSI
Fibre Channel Interface:
• 2.125-Gigabit (400 MB/sec. in full-duplex mode)
• Backward compatible with 1.0625-Gigabit
devices
• One (1) SFP (Small Form Factor Pluggable) port
• Full support for direct connect to F-port
fabric switches
• Class 2, Class 3 and Intermix ANSI Fibre
Channel Specifications
• Fibre Channel support for FC-AL, PLDA and
public loop login
• Full-duplex data transmissions
SCSI Interface:
• Two (2) independent VHDCI
68-pin SCSI connectors
• LVD Ultra3 SCSI – 160 MB/sec. max
per channel
• Backward compatible with all Single-
ended SCSI devices
• 128 LUNs per channel
Performance:
• Over 7,000 I/Os per sec.
• Up to 209 MB/sec. sustained data-transfer rate
• Memory: 128 MB for advanced data
buffering and performance
• Support for 8 concurrent XCOPY processes
Fibre Channel Compliance:
• Single bit error detection and correction (ECC)
• Multi-bit error detection
• ANSI FC-AL
• SNIA Extended Copy
• Class 2, Class 3 and Intermix
• FCP-1 and FCP-2 Fibre Channel Specifications
Management
Device Management Physical Interface:
• In-band (through Fibre Channel)
• Serial through RJ-11 serial port
• Network through 10/100 BaseT Ethernet
Port (Telnet, FTP and SNMP)
Device Management User Interface:
• Command Line Interface (CLI)
• ASCII-based menu system
• Performance reporting and Error Logging
(CLI commands)
• ATTO ExpressNAV™ integrated management
console
F i b r e
©2005 ATTO Technology, Inc. Specifications subject to change without notice.
ATTO FibreBridge
LEDs:
• FC Activity
• FC Link
• SCSI Activity Port 1, 2
• Ready
• Fault
Environmental and Physical
Characteristics
Dimensions:
• 6.193" W
• 6.299" L
Operating Environment:
• Temperature: 0 - 40º C
• Humidity: 10 - 90% non-condensing
Power:
• Input:
3.5A@5V
• Power provided: cPCI connector or
Custom 6-pin connector
Configuration:
• Single (embedded) PCB
Figure 1 - FibreBridge 2350C
Fault LED
Ready LED
RJ-11 Serial
Connector
RJ-45 Ethernet
Connector
SCSI Port 0 &
Port 1
Activity LED
SCSI ports
0 & 1
FC Activity &
Link
LED
SFP Fibre
Channel
Connector
C h a n n e l
2350C
Airflow:
• Recommended 250 LFM
• Ambient Air not to exceed 40ºC
Other
Operating Systems Supported:
• Operating system independent
SCSI ASIC
FC ASIC
Event-log Battery
Backup
On-board
Processor
Power LED
Optional
Power
Connector
cPCI
Power
Connector
Rev. 7/05

Advertisement

loading