Download Print this page
Hide thumbs Also See for allure QS3 series:

Advertisement

Available languages

Available languages

®
ALLURE
QS3 SERIES
RANGE HOOD
READ AND SAVE THESE INSTRUCTIONS
WARNING
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY
TO PERSONS, OBSERVE THE FOLLOWING:
1. Use this unit only in the manner intended by the manufacturer. If
you have questions, contact the manufacturer at the address or
telephone number listed in the warranty.
2. Before servicing or cleaning unit, switch power off at service panel
and lock the service disconnecting means to prevent power from
being switched on accidentally. When the service disconnecting
means cannot be locked, securely fasten a prominent warning
device, such as a tag, to the service panel.
3. Installation work and electrical wiring must be done by a qualified
person(s) in accordance with all applicable codes and standards,
including fire-rated construction codes and standards.
4. Sufficient air is needed for proper combustion and exhausting of
gases through the flue (chimney) of fuel burning equipment to
prevent backdrafting. Follow the heating equipment
manufacturer's guideline and safety standards such as those
published by the National Fire Protection Association (NFPA),
and the American Society of Heating, Refrigeration and Air Con-
ditioning Engineers (ASHRAE), and the local code authorities.
5. When cutting or drilling into wall or ceiling, do not damage elec-
trical wiring and other hidden utilities.
6. To reduce the risk of fire or electric shock, do not use this range
hood with an additional speed control device.
7. Ducted fans must always be vented to the outdoors.
8. To reduce the risk of fire, use only metal ductwork.
9. This unit must be grounded.
TO REDUCE THE RISK OF A RANGE TOP GREASE FIRE:
1. Never leave surface units unattended at high settings. Boilovers
cause smoking and greasy spillovers that may ignite. Heat oils
slowly on low or medium settings.
2. Always turn hood ON when cooking at high heat or when cooking
flaming foods.
3. Clean ventilating fans frequently. Grease should not be allowed
to accumulate on fan or filter.
4. Use proper pan size. Always use cookware appropriate for the
size of the surface element.
TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT
OF A RANGE TOP GREASE FIRE, OBSERVE THE FOLLOWING:*
1. SMOTHER FLAMES with a close-fitting lid, cookie sheet, or metal
tray, then turn off the burner. BE CAREFUL TO PREVENT
BURNS. If the flames do not go out immediately, EVACUATE
AND CALL THE FIRE DEPARTMENT.
2. NEVER PICK UP A FLAMING PAN — You may be burned.
3. DO NOT USE WATER, including wet dishcloths or towels - violent
steam explosion will result.
4. Use an extinguisher ONLY if:
A. You know you have a Class ABC extinguisher and you al-
ready know how to operate it.
B. The fire is small and contained in the area where it started.
C. The fire department is being called.
D. You can fight the fire with your back to an exit.
* Based on "Kitchen Fire Safety Tips" published by NFPA.
®
!
CAUTION
1. For general ventilating use only. Do not use to exhaust hazard-
ous or explosive materials and vapors.
2. To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power
unit.
3. For best capture of cooking impurities, your range hood should
be mounted so that the top of the hood is 24-30" above the cook-
ing surface.
4. Please read specification label on product for further informa-
tion and requirements.
Installer: Leave this manual with
the homeowner.
Homeowner: Operating and
Cleaning information on page 5.
NOTE
If hood is to be installed Non-Ducted:
Purchase a set of (2) non-ducted filters from your
local distributor or retailer and attach them to the
aluminum mesh filters.
TABLE OF CONTENTS
This manual is divided into sections as follows:
• "PREPARE HOOD LOCATION"
Run ductwork from roof or wall cap, and electrical wiring from
service panel - to installation location
• "PREPARE THE HOOD"
Get your hood ready for installation
• "CONNECT WIRING"
Make electrical wiring connections to hood
• "INSTALL HOOD"
Secure hood to cabinet and ductwork - install bulbs and filters
• "OPERATION"
How to use the hood controls
• "CLEANING"
Keep your hood in top working condition
• "SERVICE PARTS"
Part numbers and exploded view of hood components
• "WARRANTY"
One-year limited warranty and how to contact us
®
ALLURE
QS3 SERIES
RANGE HOOD
Page 1
Patent No.:
US D450, 829 S

Advertisement

loading

Summary of Contents for Broan allure QS3 series

  • Page 1 ® ALLURE QS3 SERIES RANGE HOOD ® Page 1 ® ALLURE QS3 SERIES Patent No.: RANGE HOOD US D450, 829 S READ AND SAVE THESE INSTRUCTIONS WARNING CAUTION TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY 1. For general ventilating use only. Do not use to exhaust hazard- TO PERSONS, OBSERVE THE FOLLOWING: ous or explosive materials and vapors.
  • Page 2: Prepare The Hood

    ® ALLURE QS3 SERIES RANGE HOOD ® Page 2 PREPARE HOOD LOCATION PREPARE HOOD LOCATION (Continued) ROOF CAP 3¼” x 10” 3¼" X 10" or 7” round 7” ROUND (For vertical (For vertical VERTICAL DUCTING discharge) discharge) SOFFIT HOUSE WIRING CABINET (Top or Back of hood) WALL CAP...
  • Page 3 ® ALLURE QS3 SERIES RANGE HOOD ® Page 3 PREPARE THE HOOD PREPARE THE HOOD (Continued) (Continued) NOTE If hood is to be installed Non-Ducted: TEFLON ® • Purchase a set of (2) Non-Ducted Filters from your COATED local distributor or retailer and attach them to the BOTTOM aluminum mesh filters.
  • Page 4 ® ALLURE QS3 SERIES RANGE HOOD ® Page 4 PREPARE THE HOOD CONNECT WIRING (Continued) TAPE WARNING: To reduce the risk of electric shock, TOP/BACK UP TO 1” make sure power is switched off at the service EDGE SIDE-TO-SIDE panel. Lock or tag service panel to prevent power from being switched on accidentally.
  • Page 5: Install Hood

    ® ALLURE QS3 SERIES RANGE HOOD ® Page 5 INSTALL HOOD OPERATION Fan: 4 push button switches. Push any button to select one of the four fan speeds. Press another button to change fan speed. Push the same button to turn fan off. A light above each fan button indicates the fan speed.
  • Page 6: Service Parts

    MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. R501032 Autotransformer (includes hardware) During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part 99010305 Aluminum Mesh Filter, 30 in. (2 in package) which is found to be defective under normal use and service.
  • Page 7 ® CAMPANA EXTRACTORA ALLURE QS3 SERIES ® SERIE QS3 ALLURE RANGE HOOD ® Page 7 Página 7 CAMPANA EXTRACTORA SERIE QS3 ® ALLURE Patent No.: US D450, 829 S LEA Y CONSERVE ESTAS INSTRUCCIONES ADVERTENCIA PRECAUCION PARA REDUCIR EL RIESGO DE INCENDIO, CHOQUE ELECTRICO, O 1.
  • Page 8 ® CAMPANA EXTRACTORA ALLURE QS3 SERIES ® SERIE QS3 ALLURE RANGE HOOD ® Page 8 Página 8 PREPARACIÓN DEL LUGAR DONDE PREPARACIÓN DEL LUGAR DONDE SE VA A INSTALAR LA CAMPANA SE VA A INSTALAR LA CAMPANA TAPA DE TECHO (continuación) CONDUCTO DE SISTEMA VERTICAL DE CONDUCTOS...
  • Page 9 ® CAMPANA EXTRACTORA ALLURE QS3 SERIES ® SERIE QS3 ALLURE RANGE HOOD ® Page 9 Página 9 PREPARACIÓN DE LA CAMPANA (continuación) PREPARACIÓN DE LA CAMPANA (continuación) NOTA Si la campana se va a instalar en un sistema sin conductos: •...
  • Page 10 ® CAMPANA EXTRACTORA ALLURE QS3 SERIES ® SERIE QS3 ALLURE RANGE HOOD ® Page 10 Página 10 PREPARACIÓN DE LA CAMPANA (continuación) CONEXIÓN ELÉCTRICA BORDE AJUSTE CINTA SUPERIOR/ LATERAL ADVERTENCIA: Para reducir el riesgo de POSTERIOR HASTA DE descargas eléctricas, asegúrese de apagar el 2.5 CM (1”) interruptor de alimentación eléctrica en el panel de servicio.
  • Page 11 ® CAMPANA EXTRACTORA ALLURE QS3 SERIES ® SERIE QS3 ALLURE RANGE HOOD ® Page 11 Página 11 OPERACIÓN INSTALACIÓN DE LA CAMPANA Ventilador: 4 conmutadores de pulsadores. Presione el mismo pulsador para apagar el ventilador. Presione cualquier pulsador para seleccionar una de las cuatro velocida- des del ventilador.
  • Page 12 Esta garantía reemplaza todas las garantías anteriores. Para calificar en la garantía de servicio, usted debe (a) notificar a Broan-NuTone al domicilio o el número de teléfono abajo, (b) dar el número del modelo y la identificación de la pieza, y (c) describir la naturaleza de Pida piezas de repuesto indicando el N.º...