PREPARE THE HOOD
UP TO 1"
SIDE-TO-SIDE
ADJUSTMENT
PIVOT
8
3¼" x 10" Ducted Discharge Only: Remove Tape from damper
flap and attach Damper/Duct Connector over knockout
opening with screws removed in Step 4 under "PREPARE THE
HOOD". Make sure damper Pivot is nearest to Top/Back Edge
of hood.
9
7" Round Ducted Discharge Only: Re-install 7" Round Duct
Plate removed in Step #1 under "PREPARE THE HOOD".
Install a 7" round damper (purchase separately). Damper flap
must open freely in direction of airflow (away from range hood).
To accomodate off-center ductwork, the Damper/Duct
NOTE
Connector can be installed up to 1-inch on either side
of hood center or the 7" Round Duct Plate can be installed up to ½"
on either side of hood center. In extreme off-center installations,
one end of the duct connector may need to be trimmed to clear the
electrical cable clamp.
BLOWER
RETAINING
WHEEL
RING
SECTIONS
MOTOR
SLOTS
10
Non-Ducted Installations Only: Require a Performance Ring
to be attached to the blower wheel.
To install ring:
1. Remove the Blower Wheel by rocking it side to side and
applying a slight force to pull wheel from motor. Remove
Retaining Ring if necessary.
2. Slide the ring onto the Small Diameter End of the wheel
and down to the Stop Edge of the wheel.
3. Reassemble wheel to motor. Make sure Tab on wheel fits
into one of the Motor Slots.
4. Push wheel down until it is locked in place.
5. Check that wheel is properly positioned as shown. Press
Sections into place if necessary. Make sure wheel turns
freely.
®
(Continued)
TAPE
DAMPER/
CONNECTOR
discharge
position shown)
TAB
SMALL DIAMETER
END
RING
STOP
EDGE
CONNECT WIRING
WARNING: To reduce the risk of electric shock,
TOP/BACK
make sure power is switched off at the service
EDGE
panel. Lock or tag service panel to prevent power
from being switched on accidentally.
DUCT
(Vertical
1
Connect House Wiring (120 VAC) to hood. Use a piece of
Cardboard to protect the cooktop, if necessary.
2
Connect house black to hood black wire, house white to hood
white wire, and house ground under Green Ground Screw.
Securely tighten cable clamp onto house wiring.
®