E. Chimney Inspection
Frequency: As necessary; at least annually before
lighting fireplace, or once every two months during
heating season.
By: Homeowner/Chimney Sweep
Confirm that termination cap remains clear and
unobstructed.
Inspect for blockages such as bird nests, leaves, etc.
Inspect for corrosion or separation.
Inspect for creosote and remove as needed, at least
every two months during the heating season.
Inspect the system at the fireplace connection and
at the chimney top.
In the event of a chimney fire, Hearth & Home
Technologies recommends replacement of the chimney
unless a CSIA Certified Chimney Sweep verifies the
chimney is suitable for continued service using the
necessary level of inspection as defined by NFPA 211.
Remove screws,
lift top cover.
Top Cover
Cap
Cap
Chimney
Slip
Section
TR344/TR342
Round
Termination Cap
Figure 4.1
Chimney & Termination Cap Cleaning
16
1. Remove the 4 screws.
Remove 4 screws
2. Remove the screen.
and lift top pan off.
3. Remove the baffle.
Cap
Chase
ST375
TS345/TS345P
Square
Termination Cap
Termination Caps
Heatilator • LM42 Owners Manual • 4087-900 • Rev A • 5/11/16
F. Creosote (Chimney) Cleaning
Frequency: As needed; at least annually before light-
ing, or once every two months during heating season.
When creosote has accumulated it shall be removed
to reduce the risk of a chimney fire.
By: Chimney Sweep
Tools Needed: Brush, allen wrench, Phillips screw-
driver
When wood is burned slowly, it produces tar and
other organic vapors, which combine with expelled
moisture to form creosote. The creosote vapors
condense in the relatively cool chimney flue of a
slow-burning fire. As a result, creosote residue
accumulates on the flue lining. When ignited, this
creosote makes an extremely hot fire.
Remove all ash from the firebox and extinguish all
hot embers before disposal. Allow the fireplace to
cool completely.
Close the door tightly.
Remove the top of the termination cap as shown in
Figure 4.1 to clean the cap and chimney.
The creosote or soot should be removed from the
chimney with a brush specifically designed for the
size of chimney in use.
Reinstall termination cap top.
Clean out fallen debris from the firebox.
Remove 2 screws from
the front and back and
lift the top off.
TCT375
Square
Terra Cotta
Termination Cap
Remove 8 screws
and lift top.
Top
Screw
DTO/DTS Series
Termination Cap
Top
Screw