SCSIPortList
SC 5300
Lists the status of all available SCSI ports.
SCSIPortList
SCSIPortReset
SC 5300
Resets the specified SCSI bus.
SCSIPortReset [sb]
SCSIPortResetOnStartup
SC 5300
Controls whether the specified SCSI bus is reset each time the
unit is powered up.
Default: enabled
set SCSIPortResetOnStartup [sb] [enabled | disabled]
get SCSIPortResetOnStartup [sb]
SCSIPortSyncTransfer
SC 5300
Controls the unit's attempts to negotiate synchronous SCSI
transfers with devices on the specified bus.
Default: enabled
set SCSIPortSyncTransfer [sb] [enabled | disabled]
get SCSIPortSyncTransfer [sb]
SCSIPortTermination
SC 5300
Configures the SCSI internal termination of the specified SCSI
port. Enabling termination allows the unit to act as a terminator
at the end of a SCSI chain.
Default: enabled
set SCSIPortTermination [sb] [enabled | disabled]
get SCSIPortTermination [sb]
SCSIPortWideTransfer
SC 5300
Controls the unit's attempts to negotiate wide SCSI transfers
with devices on the specified bus.
Default: enabled
set SCSIPortWideTransfer [sb] [enabled | disabled]
get SCSIPortWideTransfer [sb]
SCSITargetLUNs
SC 5300
Controls the maximum number of SCSI LUNs per target the unit
queries during a SCSI bus scan.
Default: 8
set SCSITargetLUNs [sb] [8 | 64]
get SCSITargetLUNs [sb]
SCSITargets
SC 5300
Lists the physical devices that are connected and running on the
specified SCSI port.
SCSITargets [sb]
SerialNumber
Displays the serial number of the unit. The serial number is a 13
character field. The first seven alphanumeric characters are an
abbreviation representing the product name. The remaining six
digits are the individual unit's number.
get SerialNumber
SerialPortBaudRate
Configures the baud rate for the unit's RS-232 serial port. The
number of data bits per character is fixed at 8 with no parity.
Default: 115200
set SerialPortBaudRate [9600 | 19200 | 38400 | 57600 |
115200]
SaveConfiguration Restart command required
get SerialPortBaudRate
SerialPortEcho
Controls if the unit echoes characters on its RS-232 port. When
enabled, all non-control character keyboard input is output to
the display.
Default: enabled
set SerialPortEcho [enabled | disabled]
get SerialPortEcho
SES
SC 5500, SC 5700
Enables support for SES enclosures that have been discovered
by the appliance.
Default: enabled
set SES [enabled | disabled]
get SES
SESAlarmTest
SC 5500, SC 5700
Turns on the specified enclosure's audible alarm at the specified
warning level. Reset turns off the alarm.
Note
The SESEnclosures command must be
executed before executing
SESAlarmTest [EnclosureIndex] [SET | RESET] [INFO |
NON-CRIT | CRIT | UNRECOV]
xvi

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 5300Faststream sc 5500

Table of Contents

Save PDF