Faststream Sc 5500 Physical Attributes; Dimensions; Cooling And Airflow; Power - ATTO Technology FastStream SC 5700 Installation And Operation Manual

Atto technology faststream storage controller installation and operation manual
Hide thumbs Also See for FastStream SC 5700:
Table of Contents

Advertisement

1.2 FastStream SC 5500 Physical Attributes

The ATTO FastStream SC 5500 is a Fibre Channel to SAS/SATA SAN storage appliance which can be
seamlessly integrated into a new or an existing storage environment.
The ATTO FastStream SC 5500 is available in a
desktop model, an industry-standard 1U form factor
for easy integration into racks and as an embeddable
board-level product.
For installation instructions for the desktop and 1U
form factor models, refer to
Storage Controller
on page 9.
For installation instructions and physical attribute
details for the embeddable model, refer to the ATTO
Embedded Storage Controller Installation and
Operation manual.

Dimensions

Width: 17.31 inches
Length: 9.9 inches
Height: 1.69 inches (1U)
Weight: approximately 8 pounds

Cooling and airflow

Operating Temperature: 5 °C-40 °C
Humidity: 10-90% non-condensing
CAUTION
CAUTION
Do not block the enclosure's vents. The
FastStream does not allow data transfer if
overheating occurs. Ambient air should
not exceed 40 °C.

Power

Input voltage: 100-240 VAC, 2.5A, 47-63 Hz
Battery-backed event log: A rechargeable Lithium
ion battery cell holds the event log memory for up to 30
days. If the FastStream has been disconnected from
power, recharging begins automatically when power is
restored to the system. The battery is fully charged
after 36 hours of continuous power application.
WARNING
WARNING
Risk of explosion if battery is removed
and/or replaced by an incorrect type.
Dispose of used batteries in accordance
with your local environmental regulations.
5
ATTO Technology Inc. FastStream SC Installation and Operation Manual
Install the FastStream
Explosionsgefahr, wenn die Batterie falsch
entfernt und/oder ersetzt wird. Entsorgen
Sie benutzte Batterien in Übereinstimmung
mit Ihren lokalen
Umweltschutzbestimmungen.

Fibre Channel ports

The two independent 4-Gigabit Fibre Channel ports
connect the FastStream SC 7500 to Fibre Channel
hosts using optical SFP connectors and multimode
fiber optic cable.
Make sure all cables are anchored securely at both
ends with the proper connectors.

SAS/SATA ports

The two (x4) 3-Gb SAS/SATA
ports connect storage devices
into the Storage Area Network
(SAN) using mini SAS 4x cable
plug connectors.

Management ports

Management is provided using the 10/100/1000 base
T Ethernet port accessible from the RJ-45 connector
or the RS-232 serial port using an RJ-11 connector.
(See
Exhibit
1.2-1).

Reset/restore factory default switch

To reset the FastStream, briefly insert a tool in the hole
in the back panel for less than three seconds. See
Exhibit
1.2-1.
To restore factory defaults, insert the tool in the hole in
the back panel for more than four seconds until the
green Ready LED blinks.

LED indicators

The LED indicators can be viewed from the connector
side and the front side of the FastStream. (See
Exhibit 1.2-2
and
Exhibit
LEDs on the connector side are:
Ready/Fault LED lights green to indicate ready,
lights yellow to show a faulted condition, and is off to
indicate not ready.
1.2-3)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 5300Faststream sc 5500

Table of Contents

Save Article as PDF