preset_i<0~19>_size
7.34 Exposure window setting per channel
Group: exposurewin_c<0~(n-1)> for n channel products
NAME
mode
win_i<0~9>_enable
win_i<0~9>_policy
win_i<0~9>_home
win_i<0~9>_size
Group: exposurewin_c<0~(n-1)>_profile for m profile and n channel product
NAME
i<0~(m-1)>_mode
<window size> <blank>
VALUE
DEFAULT
auto, custom,
auto
blc
<boolean>
0
0~1
0
<coordinate>
110,90
<window size> 100x75
VALUE
auto, custom, blc
URL Command Document for All Series391
1/7
Width and height of the preset.
(It should be set by ePreset.cgi rather
than by setparam.cgi.)
SECURITY
(get/set)
4/4
4/4
4/4
4/4
4/4
DEFAULT
SECURITY
(get/set)
auto
4/4
70
VIVOTEK
DESCRIPTION
The mode indicates
how to decide the
exposure.
auto: Use full view
as the only one
exposure window.
custom: Use
inclusive and
exclusive window.
blc: Use BLC.
Enable or disable the
window.
0: Indicate
exclusive.
1: Indicate inclusive.
Left-top corner
coordinate of the
window.
Width and height of
the window.
DESCRIPTION
The mode indicates
how to decide the
exposure.
auto: Use full view
as the only one
User's Manual - 205