MODE 5 and 6 – External Target Temperature
Adjust Menu (1 of 2)
Item Field
26
Model SF-10 Control Instructions Manual
Access
Description
Factory
MODE
Select the operating mode for the control.
Installer
BOILER MAXIMUM
Factory
Select the maximum boiler target water
temperature.
BOILER MINIMUM
Factory
Select the minimum temperature allowed for the
boiler target temperature.
FIRE DELAY
Select the amount of time required for combustion
Factory
pre-purging, ignition and the flame to be
established.
BOILER MASS
Factory
Installer
Select the thermal mass of the boiler.
Factory
STAGE DELAY
Select the minimum time delay between stages.
Installer
Note: This setting is not used in this application.
DIFFERENTIAL
Select the differential that the control is to use
Factory
when it is operating the boiler.
Note: This setting is not used in this application.
DHW BOILER TARGET
Factory
Select the boiler target temperature while heating
an indirect DHW tank.
DHW MODE
Select no priority (1) or priority (2) of indirect DHW
heating over space heating.
Factory
Note: This item is only available when MODE
is set to 5.
Range
Settings
1, 2, 3, 4, 5, 6, 7
Default = 3
120 to 225°F, OFF
(49 to 107°C, OFF)
Default = 180°F (82°C)
OFF, 80 to 180°F
(OFF, 27 to 82°C)
Default = 140°F (60°C)
0:00 to 3:00 minutes
Default = 0:10 min
(1 second increments)
1 (low mass)
2 (medium mass)
3 (high mass)
Default = 2
Au, 0:30 to 9:55 min
Default = Au
Au, 2 to 42°F
(Au, 1 to 23°C)
Default = Au
OFF, 70 to 220°F
(OFF, 21 to 104°C)
Default = 180°F (82°C)
1, 2
Default = 1