Advertisement

Quick Links

• W A R N I N G •
Please refer to the System Installation Manual for information on limitations regarding product use and
function and information on the limitations as to liability of the manufacturer.
TM
Long Range Radio
Alarm Transmitter
Installation
Manual
Version 1.4W

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the LINKS 2150 and is the answer not in the manual?

Questions and answers

Summary of Contents for DSC LINKS 2150

  • Page 1 • W A R N I N G • Please refer to the System Installation Manual for information on limitations regarding product use and function and information on the limitations as to liability of the manufacturer. Long Range Radio Alarm Transmitter Installation Manual Version 1.4W...
  • Page 2: Table Of Contents

    Table of Contents FEATURES Programmable via Keypad or Downloading Software ................... 1 EEPROM Memory ..............................1 Static/Lightning Protection ............................. 1 Supervision ................................1 Operation ................................1 SPECIFICATIONS INSTALLATION Mounting the LINKS2150 ............................1 Power Terminals + 12v – ............................2 TRBL Trouble Terminals ............................
  • Page 3: Features

    LINKS2150 near sources of interference. These include must still be programmed. sources of electrical noise such as computers, televisions • May be used with the following DSC alarm control and electric motors in appliances and heating and air panels: conditioning units, as well as large metal objects like •...
  • Page 4: Power Terminals + 12V

    Power Terminals + 12v – NOTE: Do not apply power to the unit until all wiring connec- tions are completed and the antenna is attached to the unit. Connect the power terminals (+ 12V –) to the BELL+ and COM terminals or to a separate 11.5-14Vdc, 1A power supply.
  • Page 5: Programming The Links2150

    Programming the LINKS2150 Reviewing Programmed Data • Enter the 2-digit number of the section to be reviewed. Program the LINKS2150 through Installer’s Programming at a system keypad, or via DLS-1 v6.7 downloading • LCD keypads will display the current data in the software.
  • Page 6: Links2150 Programming Sections

    LINKS2150 Programming Sections These sections will only be available if a LINKS2150 v1.4W is connected to the Keybus. [86] LINKS2150 Programming Sections [20] Module Configuration for PC1580 Module configuration is set using Zone Lights as shown below. After you enter section [20], the options that are “on”...
  • Page 7: Restore Links2150 Factory Default Programming For Pc1580

    NOTE: Sections [81] and [82] apply only to the PC1580 [96] [Installer Code] [96] v1.x. All other panels will use the reporting codes that are Restore LINKS2150 Factory Default programmed for these events in the panel. Programming for PC1580 [81] Miscellaneous Alarm Reporting Codes [993][Installer Code][993] Program 2 digit reporting codes for each of the Restore LINKS2150 Factory Default...
  • Page 8: For The Record

    For The Record Client ____________________________________________________________________________ Address _________________________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ _________________________________________________________________________________ Installer ______________________________ Installation Date ________________________ Installer’s Code _______________________ Installer’s Lockout DSC Control Panel _____________________ Software Version _______________________ Notes __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________ __________________________________________________________________________________...
  • Page 9: Links2150 Programming Worksheets

    LINKS2150 PROGRAMMING Worksheets [86] LINKS2150 Programming Sections for PC1580 [803] LINKS2150 Programming Section for PC5010, PC5015, PC5008, PC1565, PC1565-2P, PC585 [01] RF Identification Code Default I _ _____I _ _____I _ _____I _ _____I I _ _____I _ _____I _ _____I _ _____I [10] Maintenance Alarm Reporting Codes I _ _____I _ _____I...
  • Page 10: Miscellaneous Alarm Reporting Codes

    [81] Miscellaneous Alarm Reporting Codes I _ _____I _ _____I General Zone Fault Alarm I _ _____I _ _____I General System Tamper Alarm I _ _____I _ _____I General System Supervisory Alarm [82] Miscellaneous Restoral Reporting Codes I _ _____I _ _____I General Zone Fault Restore I _ _____I _ _____I General System Tamper Restore...
  • Page 11: Hook-Up Diagram

    Hook-up Diagram...
  • Page 12: Limited Warranty

    LIMITED WARRANTY Digital Security Controls Ltd. warrants that for a period of twelve months from the date of purchase, the product shall be free of defect in materials and workmanship under normal use and that in fulfilment of any breach of such warranty, Digital Security Controls Ltd.

Table of Contents