Kenmore 758.144171 Owner's Manual page 13

Table of Contents

Advertisement

SP6553
EngSpa
Manual
68192
7/8/04
9=2_
Page
13
Troubleshooting
Troub{e
Probable
Cause
Remedy
Unit will not run and no
• No Power.
• Check 120 volt power
control panel lights are
source.
illuminated.
Unit will not shut off.
• Float retainer is positioned
• Slide float retainer down to
in "Manual
Dryout" position,
normal operation
mode.
Refer to "Manual
Dryout"
section on page 7.
• Free float from obstruction.
Unit will not dry out
completely.
Bottles
continue
to empty.
Neither
bottle emptying.
Left bottle not emptying.
Fill Indicators
turn on before
bottles
are empty.
Note:
There may be a little
water still in bottle when Fill
indicator
is illuminated.
This
is normal.
• Float is not free.
• Float is positioned
in
normal
operation
mode.
, Air is entering
water bottles.
• Bottle cap plunger
missing
post in bottom of cabinet
• Dirty filters
• Right bottle contains
water
, Unit is not set up on a level
surface.
(Float will not
sense water at the rear of
the cabinet.)
, This is normal. A small
amount
of water remains
in
the cabinet
after Fill Lights
come on. Position float
retainer in "Manual
Dryout"
position to completely
dry out.
See page 7.
, Check "E-ZoFill Side-Caps"
and valve assembly
caps to
ensure
tightness.
, Check for leak in water bottles.
, Ensure gaskets for "E-Z-Fill
Side Caps" are in place.
• Check orientation of bottles.
Reposition so that bottle cap
plunger (stem) is depressed
by post in bottom of cabinet.
• Change
to fresh new filters.
(42-14911 )
, The humidifier
is designed so
the right bottle empties first.
Continue to run until both fill
lights come on.
• Position
unit level. (Some
carpet
padding
may allow
unit to sit lower in front
than
rear with the additional
weight
of water bottles
in
the front of the cabinet.
install caster pads under
front casters.
(See page 4).
CAUTION:
Use only 42-14900
EPA Begiatered
Bacteriostat
available
from
Sears
Retail
store.
Use of other water
treatment
products
may damage
the fi_ter elements.
Under
no circumstances
should
you use water
treatment
products
designed
for Boto
be_t or U_trasonic
humidifiers,
13