Delta DX-2100 Series User Manual page 40

Industrial 3g cloud router
Hide thumbs Also See for DX-2100 Series:
Table of Contents

Advertisement

DX - 2 1 00 Ser i es I nd us t r i al 3G C lo u d Ro u ter
Slave mode: This mode is suitable for the PLC to perform the read/ write
tasks on the open register of the DX-2100RW-WW.
Close: Disable this functionality.
_3
Parameters of COM
Slave Mode
3 - 2 4
Description
Baud Rate
Set up the baud rate for the serial port. Options are
2400, 4800, 9600, 19200, 38400, 57600 and
115200.
Data Bits
Set up the data bits for the serial port.
Transparent mode: 7, 8
Slave mode: 8
Stop Bits
Set up the stop bits for the serial port. Options are
1 and 2.
Parity Bits
Set up the parity bits for the serial port. Options are
None, Odd and Even.
Flow Control
Set up the flow control. Options are None, XON,
XOFF, RTS, and CTS.
MODBUS ID
Set up the MODBUS ID. The value is between 1
and 255.
MODBUS Mode
Set up the communication mode for the device.
MODBUS Timeout
Set up the timeout timer from 200ms to 3000ms. If
the set value is out of range, it will be automatically
changed to its maximum or minimum value.
Default
9600
8
1
None
None
1
MODBUS RTU
200ms

Advertisement

Table of Contents
loading

Table of Contents