Celerity Fc-84En Adapter - ATTO Technology Celerity FC-81EN Installation And Operation Manual

Atto celerity fibre channel host adapters
Hide thumbs Also See for Celerity FC-81EN:
Table of Contents

Advertisement

Celerity FC-84EN Adapter

The ATTO Celerity FC-84EN leverages two next-
generation storage technologies: PCIe 2.0
interconnect and 8-Gigabit Fibre Channel.
With 8-Gb FC speeds of up to 1600 MB/sec. per
channel, the Celerity FC-84EN supports the most
demanding application requirements, including high-
definition video, rich content databases and other
high-bandwidth environments.
ATTO Celerity host adapters are an integrated family
of advanced storage connectivity solutions that are
designed to provide reliable connectivity, intelligence
and scalability.
Technical specifications
• 4 independent Fibre Channel ports
• 8-Gigabit data transfer rates
• 1600 MB/sec. maximum full-duplex throughput
per channel
• Supports all FC topologies: fabric, arbitrated
loop and point-to-point
• ANSI Fibre Channel: FC-FS, FC-AL, FCP, FC-
AL2, FC-PLDA, FC-FLA
• Flash ROM for easy field upgrades
• FC Class 3 support
• Local management and diagnostics
• Buffer credits: 41
• ATTO Advanced Data Streaming (ADS™)
Technology
Advanced FC capabilities
• Supports SNIA HBA API
2 ATTO Technology Inc. Celerity FC Host Adapters Installation and Operation Manual
• Backward compatible with 4-Gb and 2-Gb Fibre
Channel
• Supports target and initiator modes
• Supports Windows® FDMI and WMI
Host bus specifications
• x8 mechanical and x8 electrical PCI Express
interconnect
• Conforms to PCI Express Base Spec 2.0
• Conforms to PCI Express CEM Spec 2.0
• PCI Hot Plug spec 1.0
Environmental & physical specifications
• Length: 6.6 inches
• Height: 3.987 inches
• Operating temperature: 0-40 ºC (32-113 ºF)
• Storage temperature: -40 to 70 ºC (-40 to 158 ºF)
• Relative humidity: 10 to 90% non-condensing
• 7.8 W (typical)
• 100 lf/m (minimum) airflow recommended
• RoHS compliant
External connectivity
• Easy to install full height connection bracket
• External LEDs for on-line and speed status for
each channel
• Four pluggable 8-Gb optical LC SFP+ modules
included
Software specifications
• Windows 7®, XP®, Vista®
• Windows Server® 2003, 2008
• Mac® OS X 10.4.x and up
• RedHat Enterprise Linux® 4.x (2.6.x kernesl)
• RedHat Enterprise Linux® 5.x (2.6.x kernels)
• RedHat Enterprise Linux® 6.x (2.6.x kernels)
• SUSE Linux Enterprise® 9.x (2.6.x kernels)
• SUSE Linux Enterprise® 10.x (2.6.x kernels)
• Fedora Core Linux® 7.x (2.6.x kernels)
• Fedora Core Linux® 8.x (2.6.x kernels)
• VMware ESX Server® 3.5 - 4.1

Advertisement

Table of Contents
loading

Table of Contents

Save PDF