Hilti PR 30-HVS Operating Instructions Manual page 32

Rotating laser
Hide thumbs Also See for PR 30-HVS:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 29
2
Manufacturer's certificates
1
Hilti toolbox
2.10 Operating status indicators
The tool is equipped with the following operating status indicators: Auto-leveling LED, battery charge status LED,
shock warning function deactivation LED, inclined plane mode LED, surveillance mode LED and electronic inclination
alignment LED.
2.11 LED indicators
Auto-leveling LED
Shock warning deactivation LED
Inclined plane mode LED
Surveillance mode LED
Electronic inclination alignment LED
All LEDs
2.12 Charge status of the Li‑ion battery during operation
LEDs light constantly
LED 1, 2, 3, 4
LED 1, 2, 3
LED 1, 2
LED 1
-
2.13 Charge status of the Li‑ion battery during charging while inserted in the tool
LEDs light constantly
LED 1, 2, 3, 4
LED 1, 2, 3
LED 1, 2
LED 1
-
The green LED blinks.
The green LED lights con-
stantly.
The orange LED lights con-
stantly.
The orange LED blinks.
The orange LED lights con-
stantly.
The orange LED lights con-
stantly.
The orange LED blinks.
The orange LED arrows blink.
Both orange LED arrows light
constantly.
The orange LED arrow on the
left lights
The orange LED arrow on the
right lights
All LEDs blink
LEDs blink
-
-
-
-
LED 1
LEDs blink
-
LED 4
LED 3
LED 2
LED 1
The tool is in the leveling phase.
The tool has leveled itself / is operating
normally.
The shock warning function is deactiv-
ated.
Alignment in the sloping plane.
Slope mode is active.
The tool is in surveillance mode. Align-
ment with the reference point (PRA 30)
is correct.
The tool is aligning the laser plane with
the reference point (PRA 30).
The tool is in electronic inclination align-
ment mode, the PRA 30 receives no
laser beam.
The tool is correctly aligned with the
PRA 30.
The tool must be rotated in a clockwise
direction.
The tool must be rotated in a counter-
clockwise direction.
The tool has been bumped, knocked off
level or is exhibiting some error.
Charge status C
C ≧ 75 %
50 % ≦ C < 75 %
25 % ≦ C < 50 %
10 % ≦ C < 25 %
C < 10 %
Charge status C
C = 100 %
75 % ≦ C < 100 %
50 % ≦ C < 75 %
25 % ≦ C < 50 %
C < 25 %
en
25

Hide quick links:

Advertisement

Table of Contents
loading