Symptom
The operating
noise is loud/
reverberates
The operating
sound suddenly
increases in volume
The
The wind sound
unit
changes in volume
makes
noises
The unit produces
a simmering
sound
The unit
produces a buzz
that sounds
intermittently (or
the compressor
does not activate)
When first used
The unit
produces
During drying
an odor
inside
Error message (Humidity indicator)
l
Digital display
or
is displayed
is displayed
,
, or
through
is displayed
If the symptoms persist even after following the prescribed remedies, or the error message does not
l
disappear, unplug the power cord, and contact the place of purchase.
If the supply cord is damaged, it must be replaced by the manufacturer, its services agent or similar
l
qualified persons in order to avoid a hazard.
Cause/Remedy
Check to see if the unit is on a slope or uneven surface.
l
Move to a sturdy even surface.
Check to see if the pre-filter is clogged.
l
Clean according to the maintenance procedures.
Operating the unit in small rooms or in tight spaces sometimes
l
causes the sound to reverberate.
Place a mat underneath the unit.
The sound increases when the compressor activates (3 minutes
l
after turning on the unit or during Automatic modes).
The volume of the sound differs depending on the angle of the
l
louvre.
This is the sound of the refrigerant.
l
The sound can be heard while the refrigerant stabilizes after the
unit turns on, changes modes, or stops.
This is the sound of the compressor.
l
In modes that monitor the humidity level or during drying inside,
the compressor operates intermittently causing the sound to be
heard occasionally.
The compressor does not activate after turning the unit off, or for
3 minutes after plugging the unit into a power socket. (This is to
protect the compressor from damage.)
The heat converter heats rapidly causing a brief odor. This is not a
l
malfunction.
The moisture expelled from inside the unit may smell due to
l
odorants that were not caught by the silver ion filter dissolving in
the water. This is not a malfunction.
Cause/Remedy
Check to see if the power cord is plugged into the power socket
l
properly.
Plug the power cord into the power socket properly.
Check to see if anything is blocking the air outlet.
l
Remove the obstruction, and plug the power cord into the
power socket again.
Check to see if the pre-filter is clogged.
l
Clean according to the maintenance procedures.
Malfunction
l
Take note of the error message, unplug the power cord, and
contact the place of purchase.
5