Inspection And Maintenance; Before Calling For Service - Hoshizaki FM-150KE Instruction Manual

Self-contained ice maker
Hide thumbs Also See for FM-150KE:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 4
ENGLISH
1) Slide the air filter off the louver.
2) Clean the air filter by using a vacuum cleaner. When severely clogged, use
warm water and a neutral cleaner to wash the air filter.
3) Rinse and dry the air filter thoroughly.
After cleaning, be sure to place the air filter back in position.

2. INSPECTION AND MAINTENANCE

To achieve optimum icemaker performance, the following parts need periodic inspection and maintenance:
Extruding head (upper bearing)
Housing (lower bearing)
Mechanical seal
These parts should be inspected after two years from installation or 10,000 hours of operation, whichever comes first, and once
a year afterwards. Replacement of these parts is required if wear exceeds factory recommendations.
Their service life, however, depends on water quality and environment. More frequent inspection and maintenance are
recommended in bad or severe water conditions.
Consult with your local Hoshizaki service agent about inspection and maintenance service.

3. BEFORE CALLING FOR SERVICE

[a] Error Code Indication
If the error code "E" is indicated on the display, before calling for service, check the following.
Code
E0
Possibility of water leaks. Turn OFF operation switch, and turn it ON again. If error code appears again, call for
service.
E1
Low ice production. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
E2
Water supply circuit failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for
service.
E3
Gear motor failure. Turn OFF operation switch, and turn it ON again after 10 minutes. If error code appears again, call
for service.
E4
Abnormal high side pressure. Clean air filter. Check that icemaker is properly installed according to installation manual.
Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
E5
Electric circuit failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
E8
Compressor could be overheated. Check that icemaker is properly installed according to installation manual. Turn OFF
operation switch, and turn it ON again after 10 minutes. If error code appears again, call for service.
EA
Electric circuit failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
Eb
Electric circuit failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
EC
Electric circuit failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
EE
Gear motor failure. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
EF
Supply voltage is too low. Check that voltage is in required range and icemaker is not sharing a single receptacle with
other appliances. Turn OFF operation switch, and turn it ON again. If error code appears again, call for service.
NOTICE
NOTICE
WARNING
Do not damage the refrigerant circuit.
Air Filter
Remedy
6
Louver

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents