  • EN

Available languages

  • ENGLISH, page 4
ENGLISH
I. INSTALLATION INSTRUCTIONS

1. CONSTRUCTION

Operation Panel
Front Panel (Left)

2. LOCATION

This icemaker is not intended for outdoor use.
The icemaker should not be located next to ovens, grills or other high heat producing equipment.
This appliance is not suitable for installation in an area where a water jet could be used.
In some high humidity environments, condensation may form inside the machine and drip onto the floor. Do not install where
the floor can be affected by water.
The location should provide a firm and level foundation for the icemaker.
Do not place anything on top of the icemaker or in front of the louver.
Normal operating ambient temperature should be within 5°C to 40°C. Normal operating water temperature should be within
5°C to 35°C. Operation of the icemaker, for extended periods, outside of these normal temperature ranges may affect
production capacity.
Allow the clearance specified below for proper air circulation and ease of maintenance and/or service should they be required.
Top View
Left
15cm

3. ELECTRICAL CONNECTIONS

This icemaker requires an earth that meets the national and local electrical code requirements.
Disconnect the main power supply before any maintenance, repairs or cleaning is undertaken.
Louver
Air Filter
Rear
15cm
15cm
ICEMAKER
Front
THIS APPLIANCE MUST BE EARTHED
Top Panel