13 Configure the alarm settings [Alarm]
The settings relating to Panasonic alarm protocol can be configured in this section.
Panasonic alarm protocol notification

[Panasonic alarm protocol]

Select "On" or "Off" to determine whether or not to provide notification by Panasonic alarm protocol according
to the settings for the "Alarm" and "Diag." checkboxes of "Destination of notification" below.
When an alarm is detected ("Alarm")
:
SW559
SW559
SP509
SP509
When a notification of the remaining capacity of the SD memory card has been provided ("Diag.")
When the SD memory card has become full ("Diag.")
When the SD memory card cannot be recognized ("Diag.")
Default: Off
Note
When "On" is selected, notification of the alarm occurrence will be provided to the registered destination
addresses in order (to IP address 1 first, to IP address 8 last).
[Additional alarm area data(VMD)]
Determine whether or not to send notifications for VMD alarm detection area numbers with the Panasonic
alarm protocol by selecting On/Off.
Default: Off
[Destination port]
Select a destination port for the Panasonic alarm protocol from the following.
Available range: 1 - 65535
Default: 1818
The following port numbers are unavailable since they are already in use.
20, 21, 23, 25, 42, 53, 67, 68, 69, 80, 110, 123, 161, 162, 443, 995, 10669, 10670