16 and 19 seer versions dc inverter split wall-mounted ductless heat pumps
Table of Contents

Advertisement

=
minutes. While TCDI
-6℃.
----T4<0℃,
st
nd
If the 1
condition and 2
condition items are satisfied, then the program judges if T2 has decreased
more than 5℃.When T2 has decreased more than 5℃, enter the defrosting mode.
----No matter what value T4 is, if the machine runs with T3<3℃ for more than 120 minutes and T3
keeps lower than TCDI+4℃ for more than 3 minutes, the machine will enter defrosting mode no
matter if T2 drops more than 5℃ or not.
Condition of ending defrosting:
If any one of the following items is satisfied, the defrosting will finish and the machine will turn to
normal heating mode.
----T3 rises to be higher than TCDE1℃.
----T3 keeps to be higher than TCDE2℃ for 80 seconds.
----The machine has run for 10 minutes in defrosting mode.
While TCDE1=15℃, TCDE2=8℃ for 18k,24k models. TCDE1=12℃, TCDE2=8℃ for other models.