Installation Details; Wrench Torque Sheet For Installation; Connecting The Cables - Pioneer WYB-GMFI SERIES Service Manual

16 and 19 seer versions dc inverter split wall-mounted ductless heat pumps
Table of Contents

Advertisement

6. Installation details

6.1 Wrench torque sheet for installation

Outside diameter
mm
inch
Ф6.35
1/4
Ф9.52
3/8
Ф12.7
1/2
Ф16
5/8
Ф19
3/4

6.2 Connecting the cables

The power cord of connect should be selected according to the following specifications sheet.
Rated current of appliance
>3 and ≤6
>6 and ≤10
>10 and ≤16
>16 and ≤25
The cable size and the current of the fuse or switch are determined by the maximum current indicated
on the nameplate which located on the side panel of the unit. Please refer to the nameplate before
selecting the cable, fuse and switch.
Torque
N.cm
1500(153kgf.cm)
2500(255kgf.cm)
3500(357kgf.cm)
4500(459kgf.cm)
6500(663kgf.cm)
Nominal cross-sectional area (mm²)
18
Additional tightening torque
N.cm
1600(163kgf.cm)
2600(265kgf.cm)
3600(367kgf.cm)
4700(479kgf.cm)
6700(683kgf.cm)
0.75
1
1.5
2.5

Advertisement

Table of Contents
loading

Table of Contents