3-3 PRESET ADJUSTMENTS

• PRESET screen
ADJUSTMENT
EXTERNAL
1 • Push [F-1] (PRESET) to enter the Preset menu.
METER
-PREPARATION-
-ADJUSTMENT-
2 1) Push [F-5] (ID-APC).
2) Turn the main dial to set the adjustment value to "11.0 A."
3) Push [F-7] (SET).
3 1) Connect a voltmeter to the [METER] terminal.
2) Push [F-1] (Ext Met) to enter the External Meter adjust-
4 1) Turn the main dial to set the output voltage to "0 V."
2) Push [F-7] (SET).
5 1) Turn the main dial to set the output voltage to "0 V."
2) Push [F-7] (SET).
6 1) Push [F-3] (EXIT).
2) Push [F-6] (EXIT).
OPERATION
• Returns to the preset menu.
ment mode.
• Returns to the External Meter adjustment mode.
• Returns to the main adjustment menu.
3-7
ADJUSTMENT
VALUE
ITEM/POINT
[ID APC REF]
"11.0 A"
(On the screen)
0 V
[EXT-METER A]
[EXT-METER B]
0 V