07-5
Electrical Installations
2
10
10
1
A
13
B
1 2
16
8
17
16
1 2 3 4
Distribution module
Fuses
j
10A fuse for supply of the front tent light
k
10A fuse for supply of the water pump
4
6
8
10
10
20
20
3
AUX
B
A
20
30
25
3
3
5
7
9
14
15
11
19A
12
18
1
19B
9
20
-B2
+B2
+B1
21
22
23
l
10A fuse for supply of the heating/boiler
m
20A fuse for the lights
n
20A fuse for the lights
o
30A fuse for supply of the 12V AES absorber refrigerator
p
20A fuse for the aux supply (solar charger controller)
q
25A fuses for supply of the electric step
r
3A fuse
s
3A fuse
11
Bridge circuit
12
Simulated D+ alternator output for electric step and refri-
gerator
13
Changeover switch for connecting the control panel:
A: PC100 HB ; PC 200 HB
B: PC100 HB T
14
Electrical device connection A
15
Electrical device connection B
16
Waste water tank sensor connection
17
20
Fresh water tank sensor connection
18
Control panel connection
19
A Signal input ignition - variation A
19
B Signal input ignition - variation B
20
Ground connection for electrical devices
21
Connection for negative pole for modular battery
22
Connection for positive pole for modular battery
23
Connection for positive pole for vehicle battery