Technical Data For Installation - Iveco N45 MNA M10 Installation Directive Manual

4-6 cylinders in line diesel cycle for marine application
Table of Contents

Advertisement

N45 MNA M10
10
N67 MNA M15

4. TECHNICAL DATA FOR INSTALLATION

Combustion and ventilation air when underway
Static vacuum allowed downstream of the air filter
Combustion air flow rate
Engine room ventilation air flow rate (excluding combustion air)
Static vacuum allowed in the engine room
Temperature allowed in the engine room
Temperature increase in the engine room to ext. temperature
Exhaust gas discharge
Allowed static back pressure
Exhaust gas temperature at maximum power (turbocharger inlet) °C
Flow rate at maximum power
Outer diameter of exhaust mixed with sea water
Fuel supply
Transfer pump delivery at maximum rpm
Flow rate return to tank
Fuel temperature
Inner diameter, intake pipe
Inner diameter, return pipe
Thread on pre-filter junctions
Free height below filter to replace filter
Allowed intake vacuum
Allowed on tank return pipe back pressure
Open sea water cooling line
Intake pipeline diameter
Pump delivery at maximum rpm
Sea water pump height above sea level
Allowed intake vacuum
Discharge pipeline diameter (only if dry gas exhaust)
Allowed engine inclination angles
Maximum longitudinal in continuous operation (static + dynamic) degrees/360
Maximum transverse in continuous operation (static + dynamic)
Longitudinal for oil level check with standard dipstick
insTAllATiOn direcTiVe
kPa
mmH
O
2
m
/h
3
m
/h
3
kPa
mmH
O
2
°C
°C
kPa
mmH
O
2
kg/h
mm
inches
l/h
l/h
°C
mm
mm
M
mm
kPa
mmH
O
2
kPa
mmH
O
2
mm
inches
l/h
m
kPa
mmH
O
2
mm
inches
degrees/360
degrees/360
n45 MnA M10
n67 MnA M15
≤ 3,5
≤ 350
≥ 340
≥ 1960
≤ 0,1
≤ 10
≤ 45
≤ 15
≤ 7
≤ 700
700
400
127,5
5
140
120
≤ 60
≥ 8
≥ 8
14 x 1,5
≥ 30
≤ 15
≤ 1500
≤ 10
≤ 1000
34,6
1,36
8600
≤ 2
≤ 20
≤ 2000
45
1,77
+20
± 22 30'
0 to +6
MAY 2006
≥ 510
≥ 1960
720
590

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

N67 mna m15

Table of Contents