REQUIREMENTS FOR ALCOVE OR
CLOSET INSTALLATION
_-
Explosion Hazard
Keepflammable materialsand vapors,such as gasoline,
away from dryer.
Placedryer at least 18"(46cm) abovethe floor for a
garage installation.
Failureto do so can resultin death,explosion,or fire.
, If the dryer is approved
for installation
in an
alcove or closet, it will be stated on a label on the
dryer back.
, The dryer MUST be vented to the outdoors.
, Minimum
clearance
between dryer cabinet and
adjacent
walls or other surfaces is:
0" either side
3" front
3" rear
l" top
52" from floor to overhead
cabinets
Consideration
must be given to provide adequate
clearance
for installation
and service.
, Closet ventilation
openings
required: 2 louvers
each 60 square inches (387 square cm), located 3
inches (7.6 cm) from top and bottom
of door.
Gas Dryers Only:
, No other fuel burning appliance
shall be installed
in the same closet as a gas dryer.
, The dryer must be disconnected
from the gas
supply piping during pressure testing at pressures
greater than 1,_psi (3.5 kPa).
, A 1/8 inch NPT minimum
plugged tapping,
accessible for test gauge connection,
must be
installed immediately
upstream
of the gas supply
connection
to the dryer.
MOBILE OR MANUFACTURED
HOME
INSTALLATION
,, Installation
must conform
to the
MANUFACTURED HOME CONSTRUCTION AND
SAFETY STANDARD, TITLE 24, PART 32-80 or
Standard CAN/CSA-Z240
MH, or, when such
standard
is not applicable, with AMERICAN
NATIONAL STANDARD FOR MOBILE HOME,
ANSI/NFPA NO. 50lB.
, The dryer MUST be vented to the outdoors. The
exhaust vent must be securely fastened
to a
non-combustible
portion of the mobile home.
,, The vent MUST NOT be terminated
beneath a
mobile or manufactured
home.
, The vent duct material
MUST BE METAL.
,, KIT 14-D346-33
MUST be used to attach the dryer
securely to the structure.
, The vent MUST NOT be connected
to any other
duct, vent or chimney.
, Do not use sheet metal screws or other
fastening
devices which extend into the interior
of the exhaust vent.
, Provide an opening with a free area of at least
25 square inches for introduction
of outside air
into the dryer room.
, See the sections for electrical
connection
information.