Download Print this page

PARRY PGG6 Instructions Manual page 13

Gas griddle
Hide thumbs Also See for PGG6:

Advertisement

TELEPHONE:
SERVICE (44) 01332 875665
FAX:
SERVICE (44) 01332 875536
TECHNICAL DETAILS
MODEL PGG7 GRIDDLE
Per Burner ( All figures are NET)
GAS
NATURAL G20
BUTANE
G30
PROPANE G31
G25
GAS RATE
M³/HR
NATURAL G20
0.368 M³/HR
BUTANE
G30
0.110 M³/HR
PROPANE G31
0.110 M³/HR
G25 @ 25mb
0.425 M³/HR
AIR FLOW RATE FOR
COMBUSTION 20m³/HR
Total Unit ( All figures are NET)
GAS
NATURAL G20
BUTANE
G30
PROPANE G31
G25
GAS RATE
M³/HR
NATURAL G20
0.736 M³/HR
BUTANE
G30
0.220 M³/HR
PROPANE G31
0.220 M³/HR
G25 @ 25mb
0.850 M³/HR
AIR FLOW RATE FOR
COMBUSTION 20m³/HR
INJECTORS
Natural G20 = INJECT150
Butane G30 = INJECT099
Propane G31 = INJECT099
G25 @ 25mb = INJECT150
Parry Group Limited, Town End Road, Draycott, Derby, England DE72 3PT
OPERATING PRESSURE
20mb/8"
W.G.
29mb/11.2" W.G.
37mb/14.8" W.G.
25mb/10"
W.G.
FT³/HR
12.944 FT³/HR
3.884 FT³/HR
3.884 FT³/HR
15.007 FT³/HR
150.07 FT³/HR
OPERATING PRESSURE
20mb/8"
W.G.
29mb/11.2" W.G.
37mb/14.8" W.G.
25mb/10"
W.G.
FT³/HR
25.988 FT³/HR
7.768 FT³/HR
7.768 FT³/HR
30.014 FT³/HR
300.14FT³/HR
www.parry.co.uk
INSTRUCTION REF: IN103
ISSUE NO. 6
DATE 19.10.11.
Page 13 of 17
HEAT INPUT
3.549 KW = 12110Btu/h
3.354 KW = 11443Btu/h
2.564KW = 8747Btu/h
3.51 KW = 11975Btu/h
LB/HR
0.575 LB/HR 0.261 KG/HR
0.444 LB/HR 0.202 KG/HR
HEAT INPUT
7.098 KW = 24221Btu/h
6.707 KW = 22885Btu/h
5.127 KW = 17494Btu/h
7.02 KW = 23951 Btu/h
LB/HR
1.150LB/HR
0.888 LB/HR 0.404 KG/HR
KG/HR
KG/HR
0.523 KG/HR

Advertisement

loading

This manual is also suitable for:

Pgg7