INSTRUCTION REF: IN205
ISSUE NO. 3
DATE 07.03.12
Page 1 of 18
GAS GRIDDLE INSTRUCTIONS
MODEL: PGF GRIDDLES
MODEL NUMBER:
SERIAL NUMBER:
PURCHASE DATE:
DISTRIBUTOR:
GGP6.4, 6.6, 6.8, 6.10
VALIDATE WARRANTY
SAFETY INSTRUCTIONS
INSTALLATION INSTRUCTIONS
OPERATION INSTRUCTIONS
MAINTENANCE INSTRUCTIONS
CONVERSION INSTRUCTIONS
SERVICE INSTRUCTIONS
TECHNICAL DETAILS
PARTS LIST
WARRANTY INFORMATION
Customer Information
______________________
______________________
______________________
______________________
www.parry.co.uk
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GGP6.4 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for PARRY GGP6.4

  • Page 1 INSTRUCTION REF: IN205 ISSUE NO. 3 DATE 07.03.12 Page 1 of 18 GAS GRIDDLE INSTRUCTIONS MODEL: PGF GRIDDLES GGP6.4, 6.6, 6.8, 6.10 VALIDATE WARRANTY SAFETY INSTRUCTIONS INSTALLATION INSTRUCTIONS OPERATION INSTRUCTIONS MAINTENANCE INSTRUCTIONS CONVERSION INSTRUCTIONS SERVICE INSTRUCTIONS TECHNICAL DETAILS PARTS LIST...
  • Page 2: Safety Instructions

    To avoid scratching the highly polished exterior surface of this equipment whilst in transit, the protective film on the exterior surfaces has NOT been removed. It is IMPORTANT that this protective film is peeled off before the equipment is used. www.parry.co.uk...
  • Page 3: Installation Instructions

    SEE TECHNICAL DETAILS. 4. Appliances are designed to be installed, on Parry Catering Equipment for stability, if they are fitted on any other surface they should be suitably secured, to prevent excessive movement.
  • Page 4  Screws will be placed through the work surface so the feet of the appliance can sit directly on top of the screws so appliance can not move  Sizes required : GGP6.4 295mm x 332mm  Sizes required : GGP6.6 295mm x 532mm  Sizes required : GGP6.8 295mm x 732mm ...
  • Page 5 It is recommended that Griddles be run on full gas after ignition for 10 minutes, then adjust as necessary to obtain correct cooking temperature. To remove any residue uses a scraper several times a day after cooking. Scaling will result if this is not done. Empty the fat drawer and clean every day. www.parry.co.uk...
  • Page 6: Maintenance Instructions

    MAINTENANCE INSTRUCTIONS MAINTENANCE AND SERVICE MUST ONLY BE UNDERTAKEN BY REGISTERED FITTERS. Parry advise that regular annual maintenance should be conducted by a Gas Safe registered engineer. This is essential to maintain safety and prolong life of the appliance. PLEASE NOTE THE LOW RATE ADJUSTER ON THE UNIT HAS BEEN...
  • Page 7: Conversion Instructions

     Adjust the flame to a desired low setting that will have enough heat to keep the thermocouple hot and keep the flame burning.  Wait for a couple of minutes to make sure that the flame doesn’t go out. www.parry.co.uk...
  • Page 8: Servicing Instructions

     Loosen the nut that connects the thermocouple to the aluminium part and disconnect the piezo ignitor;  In case there a tap malfunction, you should replace and there should be no attempt to oil it. YOU MUST CLEAN THE COMPONENTS OF THE UNIT AT LEAST ONCE A YEAR www.parry.co.uk...
  • Page 9: Operating Pressure

    INSTRUCTION REF: IN205 ISSUE NO. 3 DATE 07.03.12 Page 9 of 18 TECHNICAL DETAILS GGP6.4 Total Unit OPERATING PRESSURE TOTAL HEAT INPUT 20mb/8” NATURAL G20 W.G. 3.100 KW = 10578 Btu/h 29mb/11.2” W.G. BUTANE 3.100 KW = 10578 Btu/h 37mb/14.8” W.G.
  • Page 10 PROPANE G31 0.243 M³/HR 8.565 FT³/HR 0.941 LB/HR 0.427 KG/HR G25 @ 25mb 0.615 M³/HR 21.719 FT³/HR INJECTORS Natural G20 = INJECT 115 Butane G30 = INJECT 85 Propane G31 = INJECT 85 G25 @ 25mb = INJECT 115 www.parry.co.uk...
  • Page 11 PROPANE G31 0.364 M³/HR 12.864 FT³/HR 1.413 LB/HR 0.641 KG/HR G25 @ 25mb 0.922 M³/HR 32.560 FT³/HR INJECTORS Natural G20 = INJECT 115 Butane G30 = INJECT 85 Propane G31 = INJECT 85 G25 @ 25mb = INJECT 115 www.parry.co.uk...
  • Page 12 PROPANE G31 0.399 M³/HR 14.142 FT³/HR 1.554 LB/HR 0.705 KG/HR G25 @ 25mb 1.050 M³/HR 37.080 FT³/HR INJECTORS Natural G20 = INJECT 125 Butane G30 = INJECT 93 Propane G31 = INJECT 93 G25 @ 25mb = INJECT 125 www.parry.co.uk...
  • Page 13 INSTRUCTION REF: IN205 ISSUE NO. 3 DATE 07.03.12 Page 13 of 18 GAS GRIDDLES GGP6.4, 6.6, 6.8, 6.10 PART Nº PARTS DESCRIPTION 7.0.301.0060 GRILL PLATE GGP6.4 7.0.302.0060 GRILL PLATE GGP6.6 7.0.303.0060 GRILL PLATE GGP6.8 7.0.304.0060 GRILL PLATE GGP6.10 4.0.301.0010 SLEEVE ø19x1.5x33 mm GL500 4.0.301.0011...
  • Page 14 IGNITION PILOT SBF 4.0.301.0012 PLATE REAR SUPPORT ø15x34.5mm GL500 4.0.301.0033 GAS TERMOCOUPLE 250MM FASTON 8X1 4.0.301.0045 GAS INJECTOR M6x0.75 - 1.25 (GGP6.4, GGP6.10) 4.0.301.0044 GAS INJECTOR M6x0.75 - 1.15 (GGP6.6, GGP6.8) 4.0.301.0043 GAS INJECTOR M6x0.75 - 0.93 (GGP6.4, GGP6.10) 4.0.301.0042 GAS INJECTOR M6x0.75 - 0.85 (GGP6.6, GGP6.8)
  • Page 15 INSTRUCTION REF: IN205 ISSUE NO. 3 DATE 07.03.12 Page 15 of 18 www.parry.co.uk...
  • Page 16: Warranty Policy

     Please ensure you have read the section not covered under warranty to avoid any unnecessary warranty charges.  If the problem with the machine can not be resolved please contact the company that supplied you the machine. (SERVICE CALLS CAN NOT BE PLACED DIRECT WITH PARRY) www.parry.co.uk...
  • Page 17: Not Covered Under Warranty

    6 burner cooker.  Excessive carbon build up on griddle plates.  Over use of lava rock on the chargrills recommended use by Parry 2kg only.  Faulty electrics – eg, customers plug socket, plug, wiring, junction box fault, wrong fuse.
  • Page 18 Failure to pay any warranty charges will result in the customers warranty been put on hold until the bill has been settled. Any issues regarding the raised charges should be put in writing to our warranty department for further investigation. Parry Group Ltd Town End Road Draycott Derby...