Summary of Contents for PARRY PGG6

  • Page 1 Instruction Manual PGG6/PGG6P Parry Gas Griddle...
  • Page 3: Table Of Contents

    Parts List ............................15 Replacement Parts .......................... 16 Warranty Information........................ 17-18 Disposal & Recycling ........................19 Parry Catering Equipment (Midlands) Ltd, Town End Road, Draycott, Derby, DE72 3PT. Sales Tel: 01332 875544 Fax: 01332 874455 Parry-British Built for Purpose IN270-2...
  • Page 4: Product Overview

    Product Overview The powerful Parry gas griddle makes cooking steaks, burgers, bacon and eggs effortless. Constructed from durable stainless steel and with a removable waste drainage drawer, the griddle is easy to clean as less time is spent removing waste from the plate. The plate itself is made from thick steel for excellent heat retention and the adjustable thermostat dials ensure complete control during cooking.
  • Page 5: Safety Instructions

    To avoid scratching the highly polished exterior surface of this equipment whilst in transit, the protective film on the exterior surfaces has NOT been removed. It is IMPORTANT that this protective film is peeled off before the equipment is used. Parry-British Built for Purpose IN270-2...
  • Page 6: Installation Instructions

    It is recommended that the appliance be sited below a ventilating hood preferably of the extractor type incorporating a grease filter. Appliances are designed to be installed and fitted on a Parry stand for stability. If they are fitted on any other surface they should be suitably secured.
  • Page 7 All units should have a restraining cable fitted preventing the unit from being pulled away from the wall and causing the gas hose to become disconnected accidentally. Parry-British Built for Purpose IN270-2...
  • Page 8: Operating Instructions

    To remove any residue, use a scraper several times a day after cooking. Scaling will result if this is not done. Empty the fat drawer and clean every day. Parry-British Built for Purpose IN270-2...
  • Page 9: Cleaning Instructions

    Maintenance and service must only be undertaken by a qualified electrician. Parry Catering provides a complete after-sales service by offering the sales of spare parts directly to customers. Buying spares straight from the manufacturer allows customer to experience exceptional value and speedy delivery on all spare parts.
  • Page 10 Maintenance Instructions MAINTENANCE AND SERVICE MUST ONLY BE UNDERTAKEN BY REGISTERED FITTERS. Parry advise that regular annual maintenance should be conducted by a Gas Safe registered engineer. This is essential to maintain safety and prolong life of the appliance. PLEASE NOTE THE LOW RATE ADJUSTER ON THE UNIT HAS BEEN FACTORY SET AND SHOULD NOT BE ADJUSTED UNLESS BY A QUALIFIED ENGINEER IN WHICH CASE THE LOW RATE ADJUSTER SHOULD BE RE-SEALED.
  • Page 11: Replacing Faulty Components

    Refit the saddle bracket and tighten the two screws. Reconnect gas feed to injector and gas cock and tighten Refit pilot supply Refit thermocouple and tighten do not over tighten Parry-British Built for Purpose IN270-2...
  • Page 12: Fault Finding

    If this does not work, contact Ensure to hold the control knob in Unit will not stay lit engineer to replace faulty for 10 seconds whilst lighting. parts. Parry-British Built for Purpose IN270-2...
  • Page 13: Conversion Instructions

    This must only be done by a qualified Gas Safe Engineer, and as this setting has been factory sealed. Any alterations must be resealed. Model Injector Code Propane G31 @ 37mbar 14.8” W.G. PGG6 INJECT082 Nat Gas G20 @ 20mbar 8” W.G. PGG6 INJECT130 Parry-British Built for Purpose IN270-2...
  • Page 14: Technical Instructions

    17.975 PROPANE G31 0.223 7.875 0.865 0.392 AIR FLOW RATE FOR COMBUSTION 6.36 224.6 20m3/hr Model Injector Code Propane G31 @ 37mbar 14.8” W.G. PGG6 INJECT082 Nat Gas G20 @ 20mbar 8” W.G. PGG6 INJECT130 Parry-British Built for Purpose IN270-2...
  • Page 15: Service Information

    This appliance should be routinely serviced to prolong its lifetime. Parry recommends that the appliance is serviced every 12 months by a Parry authorised engineer. Failure to service your product within the initial 12-month warranty period will cause the 24-month warranty to become void.
  • Page 16: Exploded View

    Exploded View Parry-British Built for Purpose IN270-2...
  • Page 17: Parts List

    Inject 8mm Olive Part of above Injector Compression Nut Part of above Injector Lock Nut Part of above Aerator LCB00017 Bracket for Thermocouple and Electrode MBETCASSY Electrode Part of above Thermocouple Part of above *Metalwork Components Parry-British Built for Purpose IN270-2...
  • Page 18: Replacement Parts

    Replacement Parts Part Number Description PGG7 NATURAL CONVERSION KIT CONSISTS INJECT130 NATURAL INJECTOR-,PGG6, (14) SET OF LABELS IN103-4 INSTRUCTION PACK LPG CONVERSION KIT CONSISTS OF: INJECT082 LPG INJECTOR- PGG6, (14) SET OF LABEL IN103-4 INSTRUCTION PACK Parry-British Built for Purpose IN270-2...
  • Page 19: Warranty Information

    Parry and not the sale or installation date of the equipment. Please ensure you have referred to the manufacturer’s instruction before placing a warranty...
  • Page 20 Faulty electrics – e.g. customer’s plug socket, plug, overuse of lava rock on chargrills. (Recommended wiring, junction box fault, wrong fuse. use by Parry no more than 2kg.) Products must be serviced within the first 12 Appliances that have been installed in mobile...
  • Page 21: Disposal & Recycling

    Disposal & Recycling The packaging should be disposed of in accordance with the regulations in force. Parry-British Built for Purpose IN270-2...